System Configuration
Card
Priority
Card Type
Slot Priority
Maximum
Allowed
Intel DP 10 Gb SFP+ NICs, Broadcom DP 10 Gb 57412
NIC, Qlogic QLGX 10 Gb NICs
4, 7, 1, 6, 8, 3
6
Solarflare DP 10 Gb NICs*, Qlogic DP 10 Gb V1 NIC*
8, 4, 1, 7, 6
5
Qlogic DP 10 Gb SFP V1 NIC, Qlogic DP 10 Gb V2
NIC
4, 7, 1, 6
4
8
FC8 HBAs
4, 7, 1, 6, 8, 5, 3, 2
8
9
12G SAS HBA
4, 7, 1, 6, 8, 3
6
HBA330
0, 1, 3
2
10
PCIe SSD
8, 4, 7, 1, 6
5
2 CPU, 1 External fan (Right)
1
GPUs
3, 1
2
RAID (H330), RAID (H730)
0
1
RAID (H740)
0, 1, 3
2
RAID (H840)
7, 8, 6, 4
4
BOSS
1, 3, 7, 8, 6, 4
6
2
100 Gb NICs
8, 6
4
3
40 Gb NICs, 25 Gb NICs
7, 8, 6, 4
4
4
FC32 HBAs, FC16 HBAs
7, 8, 6, 4
4
5
10 Gb NICs
7, 8, 6, 4
4
6
FC8 HBAs
7, 8, 6, 4
4
7
1 Gb NICs
7, 8, 6, 4
4
8
12Gb SAS HBA
7, 8, 6, 4
4
9
HBA330
0, 1, 3
2
10
PCIe SSD
1, 3, 7, 8, 6, 4
6
2 CPU, 2 External fans
1
Dell PowerEdge Express Flash (PCIe SSD) Bridge
1, 3
2
2
GPUs
3, 6, 8, 1
4
RAID (H330), RAID (H730)
0
1
RAID (H740)
0, 1 ,3
2
RAID (H840)
4
1
BOSS
1, 3, 7, 8, 6, 4
6
3
NICs
4
1
4
12Gb SAS HBA
4
1
HBA330
0, 1, 3
2
5
PCIe SSD
1, 3, 7, 8, 6, 4
6
NOTE:
The PCIe cards with * require the cooling fan assembly (middle fans) to support.
NOTE:
Without external fans, Mellanox CX4 SP 100 Gb NIC and Intel QP 10 Gb Base-T NIC are only allowed on slot 8 and 2 CPU
configuration.
128
Installing and removing system components
Summary of Contents for EMC PowerEdge T640 D24XR
Page 23: ...Figure 16 Configuration and layout Dell EMC PowerEdge T640 overview 23 ...
Page 24: ...Figure 17 Electrical overview 24 Dell EMC PowerEdge T640 overview ...
Page 25: ...Figure 18 Memory information Dell EMC PowerEdge T640 overview 25 ...