Figure 51. Installing the drive backplane
Next steps
1.
Install the cooling fan cage assembly
.
2.
.
4.
Install the drive backplane cover
.
5. Connect the drive backplane cables to the connector on the system board.
6. Connect the drive backplane cables to the connector on the backplane.
7. Follow the procedure listed in
After working inside your system
.
Front PERC module
Removing the front mounting front PERC module
Prerequisites
1. Follow the safety guidelines listed in the
.
2. Follow the procedure listed in
Before working inside your system
3.
Remove the drive backplane cover
4. If installed,
5. Disconnect all the cables, observe the cable routing.
Steps
1. Using a Phillips #2 screwdriver, loosen the captive screws on the front PERC module.
2. Slide and pull the front PERC module to disengage from the connector on the drive backplane.
Installing and removing system components