Dell EqualLogic Configuration Guide v11.3
36
4.5.2
Partially Redundant SAN Configurations
Each of the SAN configurations shown in this section will allow host connectivity to data stored in the
SAN. These configurations are for reference only.
They are not recommended for production
deployment since they do not provide end-to-end redundant connection paths.
Single Array Controller Configurations
You can configure a Dell EqualLogic array to run using a single controller. Table 19 below shows
configurations using a single array controller.
Single Controller
Single Switch
Single NIC
Single Controller
Single Switch
Dual NIC
Single Controller
Dual Switch
Dual NIC
Table 19 Single Controller Array Configurations