background image

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Technical Guide 

 

 

 

1-socket 1U rack 

server providing 

the features you 

need without a 

lot of the 

unnecessary 

extras. 

Dell PowerEdge R210  

Summary of Contents for External OEMR XL R210

Page 1: ...Technical Guide 1 socket 1U rack server providing the features you need without a lot of the unnecessary extras Dell PowerEdge R210 ...

Page 2: ...trademarks of Microsoft Corporation in the United States and or other countries Mellanox is a registered trademark of Mellanox Technologies Inc and ConnectX InfiniBlast InfiniBridge InfiniHost InfiniRISC InfiniScale and InfiniPCI are trademarks of Mellanox Technologies Inc Red Hat is a registered trademark of Red Hat Inc in the United States and other countries Linux is a registered trademark of L...

Page 3: ... 9 Rails 21 4 10 Fans 22 4 11 Control Panel LED 22 4 12 Security 22 4 12 1 Top Cover Lock Mechanism 22 4 12 2 Bezel 22 4 12 3 Trusted Platform Module TPM 22 4 12 4 Power Switch Security 23 4 12 5 Intrusion Alert 23 4 12 6 Secure Mode 24 4 13 USB Ports 24 4 14 Battery 24 4 15 Field Replaceable Units FRU 25 4 16 User Accessible Jumpers Sockets and Connectors 25 5 Power Thermal Acoustic 26 5 1 Power ...

Page 4: ...ed Programmable Interrupt Controller APIC 35 8 11 USB Interface 35 8 12 Real Time Clock RTC 36 8 13 GPIO 36 8 14 Enhanced Power Management 36 8 15 System Management Features 36 8 15 1 TCO Timer 36 8 15 2 Processor Present Indicator 36 8 15 3 Error Code Correction ECC Reporting 36 8 15 4 Function Disable 37 8 16 System Management Bus SMBus 2 0 37 8 17 Intel Anti Theft Technology 37 8 18 Intel Virtu...

Page 5: ...17 Peripherals 61 17 1 USB 61 17 2 USB Device 61 17 3 External Storage 62 18 Packaging Options 62 Tables Table 1 Comparison of PowerEdge Server Features 8 Table 2 Comparison Overview PERC S100 and S300 12 Table 3 eSATA Modes 13 Table 4 Product Feature Summary 14 Table 5 Overall Dimensions and Weight 16 Table 6 Specific Measurements 16 Table 7 TPM Pin Signals 23 Table 8 Power Supply 24 Pins and Sig...

Page 6: ... 31 AMF Single Pack Dimensions and Weights 63 Table 32 EMF Single Pack Dimensions and Weights 63 Table 33 PowerEdge R210 Volatility 66 Table 34 Volatility Data Writing and Purpose 68 Table 35 Methodology for Data Input to Memory 69 Table 36 Methodology for Memory Protection and Clearing 71 Figures Figure 1 Server Dimensions 17 Figure 2 Front Panel View 17 Figure 3 Back Panel View 18 Figure 4 Power...

Page 7: ... of many IT environments with a short 15 5 inch chassis to allow for flexible deployment almost anywhere including space constrained environments Energy Efficiency The PowerEdge R210 incorporates Energy Smart design using a low 250 watt power supply low flow fans and logical component layout of the internal components which aids with airflow direction helping to keep the server cool and reduce noi...

Page 8: ...400 series Dual core Intel Celeron G1101 Dual core Intel Pentium G6950 Dual core Intel Core i3 530 Dual core Intel Core i3 540 processors Front Side Bus DMI 1333MHz DMI 2 5 Gb s Processors 1 1 1 Cores Dual or Quad Dual or Quad Dual or Quad L2 L3 Cache 4MB or 8MB 512K 6M Intel Xeon 8M DT proc 4 3 or 2M Chipset Intel 3420 chipset Intel 3210 chipset ICH9R Intel 3420 chipset DIMMs 4 DDR3 Unbuffered w ...

Page 9: ...ar software based Availability ECC Memory ADD in RAID TPM CTPM ECC memory Add in RAID toolless chassis Hot swap HDD Redundant PSU Quad pack LED diagnostic LCD with Hot swap HDD chassis ECC Memory Server Mgt BMC IPMI 2 0 compliant Full Dell OpenManage suite Optional iDRAC6 Express iDRAC6 Enterprise vFlash DRAC4 Full Dell OpenManage suite BMC IPMI 2 0 compliant Full Dell OpenManage suite Optional iD...

Page 10: ... rear 2 front 2 rear 2 internal Power Supplies Non redundant 250W 80 Bronze Auto Ranging 100V 240V Non redundant 345W Non redundant 350W 80 Bronze Optional redundant 400W 80 Silver Auto Ranging 100V 240V Fans Non redundant non hot swappable Non redundant non hot swappable Non redundant non hot swappable Form Factor 1U rack 1U rack 1U rack Dimensions HxWxD 42 6 x 431 x 393 7 mm w o ear and bezel 1 ...

Page 11: ... uses drives which are attached to the computer system via a built in I O interface or a processor less host bus adapter HBA The RAID function becomes active as soon as the operating system has loaded the RAID driver software Previous generations of PERC controllers have been based on Hardware RAID technology the PERC S100 and PERC S300 are based on Software RAID technology The software based RAID...

Page 12: ...pport Yes Yes Operating System Support Windows Server Only Microsoft Windows Server 2003 R2 SP2 32 64 bit Standard Enterprise Editions Microsoft Windows Server 2003 R2 SP2 32 bit Web Edition Microsoft Windows Server 2008 SP2 32 64 bit Standard Enterprise Editions Microsoft Windows Server 2008 R2 64 bit Web Standard and Enterprise Editions Microsoft Windows Server 2003 R2 SP2 32 64 bit Standard Ent...

Page 13: ...A R T Self Monitoring Analysis and Reporting Technology protection eSATA may be a good choice eSATA devices are not bootable when BIOS is set to RAID mode and are not supported as a part of Virtual Disks when in RAID mode for S100 To operate eSATA devices in the Red Hat Enterprise Linux 4 8 environment the BIOS mode must be manually switched from default AHCI mode to ATA mode Table 3 eSATA Modes M...

Page 14: ...slot RAID Controllers Internal Controllers SAS 6 iR PERC S100 software based PERC S300 software based PERC H200 External Controllers PERC 6 E with 256MB or 512MB of battery backed cache SAS 5 E PERC H800 LSI2032 PCIe SCSI HBA Drive Bays Cabled options available Up to two 2 5 3 5 SAS SATA or SSD drives Maximum Internal Storage 4TB Hard Drives 3 5 inch SATA 7 2K rpm 160GB 250GB 500GB 1TB 2TB 3 5 inc...

Page 15: ...dows Small Business Server 2008 64 bit Standard and Premium Edition Microsoft Windows Server 2003 R2 with SP2 32 bit Standard and Enterprise Edition Microsoft Windows Server 2003 R2 with SP2 64 bit Standard and Enterprise Editions Microsoft Windows Server 2008 32 bit Web Standard and Enterprise Edition Microsoft Windows Server 2008 64 bit Web Standard and Enterprise Editions Microsoft Windows Serv...

Page 16: ...e Non Redundant PSU Diagnostic LED 4 2 Dimensions and Weight Table 5 Overall Dimensions and Weight Dimensions HxWxD w o ear and bezel 1 68 x 17 x 15 5 42 6 x 431 x 393 7 mm Max Weight 17 76 lbs 8 058kg Measurements in Table 6 correspond to the diagram shown in Figure 1 below Table 6 Specific Measurements Xa Xb Ya Yb Yc Za with bezel Za without bezel Zb Zc L6 Sys Wgt Kg 434 0 482 58 42 4 N A N A 31...

Page 17: ...rEdge R210 Technical Guide 17 Figure 1 Server Dimensions Zb goes to the nominal rear wall external surface where the motherboard I O connectors reside 4 3 Front Panel View and Features Figure 2 Front Panel View ...

Page 18: ...st be in the form of a standard Power icon Figure 4 Power Button LED 4 5 2 System Status ID LED The System Status ID LED present on non modular rack dense and rackable tower PowerEdge servers has the following states No light System is in the off state S5 or mechanical no AC power Blinking Amber System fault error condition Steady Blue Normal operating state S0 Blinking Blue System ID engaged This...

Page 19: ...Dell PowerEdge R210 Technical Guide 19 4 7 Side View Figure 5 Side View ...

Page 20: ...Dell PowerEdge R210 Technical Guide 20 4 8 Internal Chassis View Figure 6 Internal Chassis View ...

Page 21: ...oles or tooled mounting in 4 post threaded and 2 post racks The R210 rails must first be attached to the sides of the system and then inserted into the cabinet members installed in the rack For additional information regarding rail options for the R210 see Section 13 Figure 7 R210 Static Rails Figure 8 R210 Mounted In Four Post Square Hole Rack ...

Page 22: ...over This lock must be unlocked and the cover removed to access the internal components 4 12 2 Bezel The bezel lock is located on the front of the bezel and provides security for the system by preventing access to optical disk drives and the Power button 4 12 3 Trusted Platform Module TPM The PowerEdge R210 uses a TPM 1 2 compliant encryption chip solution on the system board with BIOS support wor...

Page 23: ..._LAD2 9 GND 12 GND 10 TPM 33MHz Clock 11 TPM 14MHz Clock 4 12 4 Power Switch Security The LED control panel is designed so the power switch cannot be accidentally turned on or off In addition in BIOS there is an optional setting in the CMOS setup to disable the power switch 4 12 5 Intrusion Alert The intrusion switch snaps into the chassis located under the side cover The intrusion switch detects ...

Page 24: ...on the control panel or set up a system password See the BIOS specification in the Hardware Owner s Manual for information 4 13 USB Ports The PowerEdge R210 has two internal USB ports Figure 11 Internal USB Ports 4 14 Battery A replaceable lithium battery CR2032 is mounted on the motherboard to provide backup power for the real time clock and CMOS RAM in the Platform Controller Hub PCH ...

Page 25: ...mber part revision level and serial number This information is used by the SEL system event log and the BMC baseboard management controller Parts available for field replacement include CMOS battery Expansion card Front bezel HDD I O panel Memory ODD Power supply Processor Processor shroud System board System fan 4 16 User Accessible Jumpers Sockets and Connectors See the Hardware Owner s Manual ...

Page 26: ...mmodate the power increase with no need to re spin the board The VRD is integrated onto the planar and is not field upgradeable 5 2 Power Supply Connectors on the Planar There are 2 separate power supply connectors on the planar One connector is an ATX connector 2x12 and the other one is a 2x2 connector to provide an additional two pins for 12V The connector Pin definition 2 x 12 power connector i...

Page 27: ... min 5 3 4 Maximum Shock Operating One shock pulse in the positive z axis one pulse on each side of the system of 31 G for 2 6 ms in the operational orientation Storage Six consecutively executed shock pulses in the positive and negative x y and z axes one pulse on each side of the system of 71 G for up to 2 ms Six consecutively executed shock pulses in the positive and negative x y and z axes one...

Page 28: ...039 BTU per hour maximum Efficiency 20 to 100 Load 82 85 115 VAC 82 85 230 VAC 1 Does not include the power supply handle or ejection tab 5 5 ENERGY STAR Compliance See the ENERGY STAR Compliance results on Dell com 5 6 Thermal The thermal design of the PowerEdge R210 reflects the following Closed loop thermal control algorithm Closed loop thermal control method uses feedback temperatures to dynam...

Page 29: ...of PowerEdge R210 is not dependent upon the hardware configuration of the system The table below shows the noise levels of the PowerEdge R210 with maximum configuration Table 11 Acoustical Specifications Configurations 23 2 C Operating Mode LWA UL Bels LpA dBA PROMINENT TONES CPU DIMM ODD HDD Intel Xeon X3450 2 66 GHz 4 x 4GB 1 X DVD RW 4 x 3 5 SAS 450 GB 15000 RPM Standby 2 8 16 None Idle 6 5 49 ...

Page 30: ...Dell PowerEdge R210 Technical Guide 30 bottom at 75 cm from the floor The acoustic transducer is at front bystander position ref ISO7779 1999 Section 8 6 2 ...

Page 31: ...33MHz Intel Xeon X3450 2 67GHz 95W 8M 4C 1333MHz Intel Xeon X3460 2 8GHz 95W 8M 4C 1333MHz Intel Xeon X3470 2 93GHz 95W 8M 4C 1333MHz Intel Xeon L3426 1 86GHz 45W 8M 4C 1333MHz Intel Core i3 540 3 06GHz 73W 4M 2C 1333MHz Intel Core i3 530 2 93GHz 73W 4M 2C 1333MHz Intel Pentium G6950 2 8GHz 73W 3M 2C 1066MHz Intel Celeron G1101 2 26GHz 73W 2M 2C 1066MHz Intel Xeon L3406 2 26GHz 30W 4M 2C 1066MHz 6...

Page 32: ...1333 w ECC 4GB DDR3 UDIMM 1066 w ECC 4GB DDR3 UDIMM 1333 w ECC Table 13 Supported Processor Configurations System Capacity System Memory Speed DIMM Speed DIMM_T ECH DIMM Capacity NUM_DI MM Slot NUM_ Rank Data Width 1GB 1066 1066 UDIMM 1 1 1 1 X8 1GB 1333 1333 UDIMM 1 1 1 1 X8 2GB 1066 1066 UDIMM 1 2 1 2 1 X8 2GB 1333 1333 UDIMM 1 2 1 2 1 X8 4GB 1066 1066 UDIMM 1 4 1 2 3 4 1 X8 4GB 1066 1066 UDIMM ...

Page 33: ...210 planar provides four 72 bit 240 pin sockets for DIMM memory modules These modules are DDR3 800 1066 1333 Unbuffered DDR SDRAM DIMMs The modules are configured as 72 bits wide to provide for ECC The memory controller in the CPU performs the ECC The system supports a minimum of 1GB upgradeable to 16 of RAM using the following DIMM sizes 1GB DIMM Module 2GB DIMM Module 4GB DIMM Module 7 4 Speed T...

Page 34: ...dent DMA operation on up to six ports and supports data transfer rates of up to 3 0 GB s 300MB s The SATA controller contains two modes of operation a legacy mode using I O space and an AHCI mode using memory space Software that uses legacy mode will not have AHCI capabilities The Ibex Peak supports the Serial ATA Specification Revision 1 0a The Ibex Peak also supports several optional sections of...

Page 35: ...t modes are supported on the LPC interface The timer counter block contains three counters that are equivalent in function to those found in one 82C54 programmable interval timer These three counters are combined to provide the system timer function and speaker tone The 14 31818 MHz oscillator input provides the clock source for these three counters The Ibex Peak provides an ISA Compatible Program...

Page 36: ...ircuit permits software independent entrance to low power states The Ibex Peak contains full support for the Advanced Configuration and Power Interface ACPI Specification Revision 3 0a 8 15 System Management Features In addition to Intel AMT the Ibex Peak integrates several functions designed to manage the system and lower the total cost of ownership TCO of the system These system management funct...

Page 37: ...eive Byte Write Byte Word Read Byte Word Process Call Block Read Write and Host Notify Ibex Peak s SMBus also implements hardware based Packet Error Checking for data robustness and the Address Resolution Protocol ARP to dynamically provide address to all SMBus devices 8 17 Intel Anti Theft Technology The Ibex Peak introduces a new hardware based security technology which encrypts data stored on a...

Page 38: ... to ensure device connectivity during the board manufacturing process The JTAG interface allows system manufacturers to improve efficiency by using industry available tools to test the Ibex Peak on an assembled board Since JTAG is a serial interface it eliminates the need to create probe points for every pin in an XOR chain This eases pin breakout and trace routing and simplifies the interface bet...

Page 39: ...ring pre boot Dell Server Assistant 7 0 support System Service support iDRAC supported Error logging via ESM ACPI 2 0 support S0 OS S4 S5 states I2O v1 5 ready Selectable Boot support based on BIOS Boot Specification v1 01 CD ROM Boot 1 0 Remote BIOS Update support Remote Configuration Interface RCI support Console redirection via COM1 PXE support based on Preboot Execution Environment Specificati...

Page 40: ...OS S4 9 3 Power Management Modes 9 3 1 Dell Active Power Controller The Dell Active Power Controller DAPC is a Dell proprietary implementation that provides improved performance watt over the OS implementation of Intel s DBS DAPC is implemented in system BIOS and uses hardware level counters etc to determine hardware utilization The BIOS uses this information to determine when to change the proces...

Page 41: ...nce the location of the bits is given to the OS in the FACP table Thus a driver can directly access bits to control a device s power management Generic features have defined enable and status bits but the functionality is not fully visible to the OS Dell provides ASL code to handle the details of generic features allowing the OS to intelligently communicate with system specific hardware Table 15 S...

Page 42: ...South Bridge For detailed explanation on how this feature works please look at BIOS Power Management specification located in Design Docs under R310 engineering Table 16 Power Profiles that R210 BIOS will Expose in BIOS Setup Maximum Performance DBPM Disabled BIOS will set P State to MAX Memory frequency Maximum Performance Fan algorithm Maximum Performance OS Control Enable OS DBPM Control BIOS w...

Page 43: ... PowerEdge R210 Technical Guide 43 10 I O Slots 10 1 Overview The PowerEdge R210 system provides Riser support x16 PCIe card Gen2 link x16 Support x16 bandwidth card under 25W Figure 13 PCIe x16 Riser Card ...

Page 44: ...ral Registers Integrated Memory Controller Target Address Decoder Integrated Memory Controller Test Registers Integrated Memory Controller Channel 0 Control Integrated Memory Controller Channel 0 Address Integrated Memory Controller Channel 0 Rank Integrated Memory Controller Channel 0 Thermal Control Integrated Memory Controller Channel 1 Control Integrated Memory Controller Channel 1 Address Int...

Page 45: ...I Controller 2 PCI Express Port 1 PCI Express Port 2 PCI Express Port 3 PCI Express Port 4 PCI Express Port 5 PCI Express Port 6 PCI Express Port 7 PCI Express Port 8 USB HS EHCI Controller 1 DMI to PCI Bridge LPC Controller1 SATA Controller 1 o Non AHCI and Non RAID Mode Ports 0 1 2 and 3 o Desktop Non AHCI and Non RAID Mode Ports 0 and 1 o AHCI Mode Ports 0 5 o AHCI Mode Ports 0 1 4 and5 o RAID ...

Page 46: ... S300 SW RAID PCIe x8 1 1 Dell PERC H200 HW RAID PCIe x8 1 1 External Storage Controllers Dell SAS 5E Adapter PCIe x8 1 1 Dell PERC 6E Adapter 256MB PCIe x8 1 1 Dell PERC 6E Adapter 512MB PCIe x8 1 1 6Gbps SAS HBA PCIe x8 1 1 Dell PERC H800 PCIe x8 1 1 Optional NICs Dell LSI2032 PCIe HBA SCSI Adapter PCIe x4 1 1 Intel Gigabit ET Dual Port Server Adapter PCIe x4 1 1 Broadcom NetXtreme II 5709 Dual ...

Page 47: ...via a PCI Express x4 gen2 link Broadcom 5716 does not support TOE TCP Offload Engine The chip provides two Gigabit Ethernet ports There are two RJ 45 connectors with integrated magnetic and LED on the rear of the system The firmware for the LOM chip resides in a flash part The PowerEdge R210 supports Wake on LAN WOL from either port For listing of NICs supported on the R210 please see Section 10 1...

Page 48: ...TA via add on storage controller Customer must be selected at point of purchase This is not an upgrade option for APOS 11 2 Drives Table 20 Available Drives Drive Specifications HDD Bays 2 x 3 5 or 2 x 2 5 Cabled only HDD SATA 3 5 7 2K 160 250 or 1000GB 2000GB HDD Near Line SAS 3 5 7 2K 1000GB 2000GB HDD SAS 3 5 15K 146 300 or 450GB 600GB 3 5 10K 600GB 2 5 10K 146 or 300GB HDD SSD 2 5 or 50GB 100G...

Page 49: ...SATA RAID card No RAID S300 with 2 HDDs 2 2 6 ASSR0CBL Add in SAS SATA RAID card RAID 0 S300 2 2 7 ASSR1CBL Add in SAS SATA RAID card RAID 1 S300 2 2 8 ASSCBL Add in SAS SATA RAID card No RAID SAS 6 iR H200 1 2 9 ASSR0CBL Add in SAS SATA RAID card RAID 0 SAS 6 iR H200 2 2 10 ASSR1CBL Add in SAS SATA RAID card RAID 1 SAS 6 iR H200 2 2 11 4 Optical Disk Drive ODD The PowerEdge R210 will support up t...

Page 50: ...e Drives PV DAS PowerVault MD1000 PowerVault MD3000 PowerVault MD1120 External TBU PowerVault RD1000 PowerVault 114X PowerVault DAT 72 PowerVault LTO 3 060 PowerVault 110T LTO 3 PowerVault LTO4 120 External TBU Automation PowerVault ML6000 PowerVault 124T PowerVault TL2000 TL4000 ...

Page 51: ...ated in Winbond WPCM450 BMC controller 640x480 60 72 75 85 Hz 8 16 32 bit color 800x600 60 72 75 85 Hz 8 16 32 bit color 1024x768 60 70 75 85 Hz 8 16 32 bit color 1280x1024 60 75 85 Hz 8 16 bit color 1280x1024 60 Hz 32 bit color 12 2 Audio The PowerEdge R210 does not support audio sound card or speakers ...

Page 52: ...provide their own screws when mounting the rails in threaded or 2 post racks Table 23 PowerEdge R210 Rail Information Rail Identifier Mounting Interface Rail Type Rack Types Supported 4 Post 2 Post Square Round Thread Flush Center A4 ReadyRails Generic Static Yes Yes Yes Yes Yes The adjustment range of the rails is a function of the type of rack in which they are being mounted The min max values l...

Page 53: ...ad N A Windows Small Business Server 2008 X64 Standard FI N A Premium Windows Server 2008 x32 bit x86 Web Test Only WHQL Standard Enterprise x64 Hyper V role enabled except for foundation Web Test Only WHQL Standard Foundation Enterprise Windows Server 2003 R2 32 bit x86 Standard Test Only WHQL Enterprise x64 Standard Test Only WHQL Enterprise Windows Server 2008 SP2 X86 Web FI WHQL WLK1 4 Standar...

Page 54: ...64 Installation Factory Install Logo Certification Red Hat Enterprise Linux 4 8 x86 64 ES DIB NFI Yes x86 ES DIB NFI Yes Red Hat Enterprise Linux 5 3 x86 64 Enterprise FI Yes x86 Enterprise DIB NFI Yes Novell SUSE Linux Enterprise S10 SP3 x86 64 ES DIB NFI Yes Novell SUSE Linux Enterprise S11 X86 64 ES FI Yes ...

Page 55: ...ded VMware ESXi 4 update 1 Download version VMWare ESX 3 5 1 Supported not offered through Dell No FI nor DIB VMWare ESXi 3 5 1 Supported not offered through Dell No FI or DIB PlateSpin PowerConvert Website download fulfillment instructions are DIB Vizioncore suite vRanger Pro vConverter vReplicator vFoglight Website download fulfillment instructions are DIB ...

Page 56: ...ehensive one to one systems management solution designed for system administrators to manage systems locally and remotely on a network OMSA allows system administrators to focus on managing their entire network by providing comprehensive one to one systems management Management Console Our legacy IT Assistant console is also included as well as tools to allow access to our remote management produc...

Page 57: ...AC features require the installation of the optional iDRAC6 Enterprise card 16 4 Lifecycle Controller and Unified Server Configurator Embedded management is comprised of four key components Dell Lifecycle Controller Dell Unified Server Configurator iDRAC6 Integrated Dell Remote Access Controller vFlash virtual flash media Lifecycle Controller powers the embedded management features It is integrate...

Page 58: ...with a Lifecycle Controller the iDRAC6 Express offers the following key features Graphical web interface Standard based interfaces Server Sensor monitoring and fault alerting Secure operation of remote access functions including authentication authorization and encryption Power control and management with the ability to limit server power consumption and remotely control server power states Advanc...

Page 59: ...sh Media Interface and Standards Support IPMI 2 0 Web based GUI SNMP WSMAN SMASH CLP Racadm command line Conductivity Shared Failover Network Modes IPv4 VLAN Tagging IPv6 Dynamic DNS Dedicated NIC Security and Authentication Role based Authority Local Users Active Directory SSL Encryption Remote Management and Remediation Remote Firmware Update Server power control Serial over LAN with proxy Seria...

Page 60: ... Boot capture Serial over LAN Virtual media Virtual console Virtual console sharing Virtual flash Monitoring Sensor Monitoring and Alerting Real time Power Monitoring Real time Power Graphing Historical Power Counters Logging Features System Event Log RAC Log Trace Log BMC availability through OpenManage ...

Page 61: ... Table 29 listed from lowest to highest priority in a 4 controller design Internal USB ports connected to internal persistent storage devices have an enable disable function independent of the other ports present in the system Table 29 USB Controller Priorities USB Controller Function If Disabled 4 Lowest Internal USB peripherals No other Controller is disabled 3 Front USB Controller 4 is disabled...

Page 62: ...External Storage External Optical Drive Optional USB DVD ROM PowerVault DAS MD1000 JBOD MD3000 RBOD MD1120 2 5 SAS SATA JBOD External TBU RD1000 USB PV114T 2U DAT 72 SCSI LTO3 060 SCSI LTO3FH SCSI LTO4 120 HH and FH SAS External TBU Automation ML6000 PV124T TL2000 TL4000 ...

Page 63: ...idth 61 cm 24 Depth 26 7 cm 10 5 System packed out weight PowerEdge R210 9 71 kg 21 42 lbs Cushion 0 42 kg 93 lbs Corrugated Box 2 75 kg 6 05 lbs Total Weight 12 88 kg 28 4 lbs Table 32 EMF Single Pack Dimensions and Weights INSIDE DIMENSIONS OUTSIDE DIMENSIONS WEIGHT Length 61 9 cm 24 38 Width 59 4 cm 23 38 Depth 24 1 cm 9 50 Length 63 5 cm 25 00 Width 61 cm 24 Depth 27 3 cm 10 75 System packed o...

Page 64: ...Dell PowerEdge R210 Technical Guide 64 Figure 16 Packaging ...

Page 65: ...ealand Class A NRCS SABS South Africa Class A CCC China Class A KCC Korea Class A UL 60950 1 CAN CSA C22 2 No 60950 1 EN 60950 1 IEC 60950 1 IRAM Argentina NOM Mexico Bellis Belarus Koncar Croatia TUV GS Germany SII Israel CKT Kazakhstan KEBS Kenya INSM Moldova Soncap Nigeria Nemko Norway GOST Russia KVALITET Serbia Bosnia Herzegovina Montenegro UKRTEST Ukraine UZBEKISTAN GOST Uzbekistan KUCAS Kuw...

Page 66: ...on Data Y U7 1 512KB FLASH NOR iDRAC6 Controller ROM Y U_IBM C1 1 4KB ROM iDRAC6 Controller RAM Y U_IBM C1 1 8KB RAM System CPLD Y U_CPL D1 1 1200 Macro cells Internal Flash EEPROM System CPLD Y U_CPL D1 1 1KB RAM iDRAC6 Express Internal Flash Y U_EM MC 1 1GB NAND FLASH System RAM Y DIMM_ A1 DIMM_ A2 DIMM_ B1 DIMM_ B2 4 up to 4 DIMMs 16GB RAM TPM ID EEPROM Plug in module only Y U_SEE PROM 1 256B E...

Page 67: ...FRU Y U_IBM C_FRU 1 4KB EEPROM iDRAC6 Boot Block Flash Y IBMC_ SPI 1 16MB FLASH NOR Trusted Platform Module Y N U_TPM 1 1 128 bytes EEPROM Chipset CMOS Y U_PCH 1 1 256B Battery backed RAM Control Panel Internal USB Y USB3 USB4 2 User selectable License key hard set ROM or user choice iDRAC6 Enterprise vFlash Y J_SD conne ctor 1 1GB Secure Digital NAND Flash ...

Page 68: ... System Services Repository i e Unified Server Configurator OS drivers diagnostics rollback versions of various programmables System CPLD volatile Yes System OS RAM iDRAC6 Express Internal Flash No Not used System RAM NO iDRAC internal RAM TPM ID EEPROM Plug in module only No BIOS binding of plug in module to a particular planar TPM Binding EEPROM China only No BMC OS VGA frame buffer iDRAC6 SDRAM...

Page 69: ...will not operate LOM Configuration Data Loading flash memory requires a vendor provided firmware file and loader program which is executed by booting up the system from a floppy or OS based executable containing the firmware file and the loader LOMs loaded with arbitrary data in firmware memory will not operate iDRAC6 Controller RAM iDRAC embedded system System CPLD Loading flash memory requires a...

Page 70: ... floppy or OS based executable or out of band firmware updates across the management network Bad contents yield the iDRAC inoperable and unrecoverable in the customer environment The lifecycle log is automatically updated by the iDRAC as various system component firmware hardware and software versions change Trusted Platform Module Using TPM enabled operating systems except in China where TCM is u...

Page 71: ...ram this ROM Not user clearable iDRAC6 Controller ROM protected permanently by hardware Not clearable iDRAC6 controller RAM n a iDRAC reset System CPLD non volatile Requires special system specific utility Not possible with any utilities or applications and system is not functional if corrupted removed System CPLD volatile Not accessible Not clearable iDRAC6 Express Internal Flash Writes are proxi...

Page 72: ...iDRAC does not function as expected if corrupted removed Lifecycle log is clearable only in a factory environment System Event Log is user clearable Trusted Platform Module SW write protected F2 Setup option Chipset CMOS N A BIOS only control Planar NVRAM_CLR jumper or by removal of AC cord cover and coin cell battery then waiting 30 seconds prior to replacement of battery cover and AC cord F2 sys...

Reviews: