The C-Series and S-Series cannot count both packets and bytes; when you enter the count
byte options, only bytes are incremented.
The
monitor
option is relevant in the context of flow-based monitoring only. For more
information, refer to
Port Monitoring
.
Most ACL rules require one entry in the CAM. However, rules with TCP and UDP port operators
(for example, gt, lt, or range) may require more than one entry. The range of ports is configured
in the CAM based on bit mask boundaries; the space required depends on exactly what ports
are included in the range.
Example
An ACL rule with a TCP port range of 4000–8000 uses eight entries in the CAM.
Rule# Data Mask From To #Covered
1 0000111110100000 1111111111100000 4000 4031 32
2 0000111111000000 1111111111000000 4032 4095 64
3 0001000000000000 1111100000000000 4096 6143 2048
4 0001100000000000 1111110000000000 6144 7167 1024
5 0001110000000000 1111111000000000 7168 7679 512
6 0001111000000000 1111111100000000 7680 7935 256
7 0001111100000000 1111111111000000 7936 7999 64
8 0001111101000000 1111111111111111 8000 8000 1
Total Ports: 4001
Example
An ACL rule with a TCP port lt 1023 uses only one entry in the CAM.
Rule# Data Mask From To #Covered
1 0000000000000000 1111110000000000 0 1023 1024
Total Ports: 1024
Related
Commands
ip access-list extended
– creates an extended ACL.
permit
– assigns a permit filter for IP packets.
permit udp
– assigns a permit filter for UDP packets.
permit udp
Configure a filter to pass UDP packets meeting the filter criteria.
C-Series, E-Series, S-Series, Z-Series
Syntax
permit udp {
source mask
| any | host
ip-address
} [
operator port
[
port
]] {
destination mask
| any | host
ip-address
} [dscp]
[
operator port
[
port
]] [count [byte] | log] [order] [monitor]
[fragments]
To remove this filter, you have two choices:
•
Use the
no seq
sequence-number
command if you know the filter’s sequence
number.
•
Use the
no permit udp {
source mask
| any | host
ip-address
}
{
destination mask
| any | host
ip-address
command.
251
Summary of Contents for Force10 Z9000
Page 1: ...FTOS Command Line Reference Guide for the Z9000 System FTOS 9 1 0 0 ...
Page 96: ...96 ...
Page 194: ...194 ...
Page 312: ...312 ...
Page 540: ...540 ...
Page 546: ...546 ...
Page 560: ...560 ...
Page 566: ...566 ...
Page 590: ...action act UpdateCounter param0 1 0x01 param1 0 0x00 output truncated 590 ...
Page 624: ...624 ...
Page 638: ...638 ...
Page 648: ...648 ...
Page 659: ...Related Commands show gvrp displays the GVRP configuration 659 ...
Page 660: ...660 ...
Page 834: ...834 ...
Page 854: ...854 ...
Page 906: ...906 ...
Page 914: ...914 ...
Page 976: ...976 ...
Page 990: ...990 ...
Page 1006: ...1006 ...
Page 1008: ...1008 ...
Page 1026: ...1026 ...
Page 1145: ...10 211 1 2 Outgoing interface list GigabitEthernet 8 0 1145 ...
Page 1146: ...1146 ...
Page 1156: ...1156 ...
Page 1166: ...1166 ...
Page 1180: ...1180 ...
Page 1258: ...1258 ...
Page 1272: ...1272 ...
Page 1394: ...1394 ...
Page 1400: ...1400 ...
Page 1410: ...1410 ...
Page 1424: ...1424 ...
Page 1444: ...1444 ...
Page 1468: ...Version 8 3 8 0 Introduced on the S4810 1468 ...
Page 1470: ...1470 ...