Field
Description
Port
Displays the egress interface. Use the second half of the entry to
determine the interface. For example, in the entry 17cl CP, the CP is
the pertinent portion.
•
CP = control processor
•
Gi = Gigabit Ethernet interface
•
Te = 10 Gigabit Ethernet interface
Example
FTOS#show ip cam stack-unit 0 port-set 0 10.10.10.10/32 longer-
prefixes
Destination EC CG V C VId Mac-Addr Port
----------------- -- -- - ------ --------------------
10.10.10.10 0 0 1 1 0 00:00:00:00:00:00 3f01 CP
FTOS#
Usage
Information
The following describes the
show ip cam ecmp-group
command shown in the Example
below.
Field
Description
Prefix Length
Displays the prefix-length or mask for the IP address configured on
the linecard 0 port pipe 0.
Current Use
Displays the number of routes currently configured for the
corresponding prefix or mask on the linecard 0 port pipe 0.
Initial Size
Displays the CAM size allocated by FTOS for the corresponding
mask. The CAM size is adjusted by FTOS if the number of routes for
the mask exceeds the initial allocation.
Example (ECMP-
Group)
FTOS#show ip cam stack-unit 0 po 0 ecmp-group detail
Destination EC CG V C VId Mac-Addr Port ECMP Group-Index
----------------- -- -- - ----- ---------------- -------------
1.1.1.2 0 0 1 0 0 00:01:e8:8a:d6:58 0004 Te 0/3 -
2.1.1.2 0 0 1 0 0 00:01:e8:8a:d6:58 0009 Te 0/8 -
1.1.1.1 0 0 1 1 0 00:00:00:00:00:00 3f01 CP -
2.1.1.1 0 0 1 1 0 00:00:00:00:00:00 3f01 CP -
1.1.1.0 0 0 1 1 0 00:00:00:00:00:00 3f01 CP -
2.1.1.0 0 0 1 1 0 00:00:00:00:00:00 3f01 CP -
100.1.1. 0 1 0 1 0 0 00:01:e8:8a:d6:58 0004 Te 0/3 0
100.1.1. 0 1 0 1 0 0 00:01:e8:8a:d6:58 0009 Te 0/8 0
0.0.0.0 0 0 1 1 0 00:00:00:00:00:00 3f01 CP -
FTOS#
Example
(Member-Info)
FTOS#show ip cam stack-unit 0 po 0 ecmp-group member-info
detail
Group Index Member Count Mac-Addr Port VLan ID Gateway
----------- ------------------------------- ------------------
0 2 00:01:e8:8a:d6:58 Te 0/3
0 1.1.1.2
00:01:e8:8a:d6:58 Te 0/8 0 2.1.1.2
FTOS#
812
Summary of Contents for Force10 Z9000
Page 1: ...FTOS Command Line Reference Guide for the Z9000 System FTOS 9 1 0 0 ...
Page 96: ...96 ...
Page 194: ...194 ...
Page 312: ...312 ...
Page 540: ...540 ...
Page 546: ...546 ...
Page 560: ...560 ...
Page 566: ...566 ...
Page 590: ...action act UpdateCounter param0 1 0x01 param1 0 0x00 output truncated 590 ...
Page 624: ...624 ...
Page 638: ...638 ...
Page 648: ...648 ...
Page 659: ...Related Commands show gvrp displays the GVRP configuration 659 ...
Page 660: ...660 ...
Page 834: ...834 ...
Page 854: ...854 ...
Page 906: ...906 ...
Page 914: ...914 ...
Page 976: ...976 ...
Page 990: ...990 ...
Page 1006: ...1006 ...
Page 1008: ...1008 ...
Page 1026: ...1026 ...
Page 1145: ...10 211 1 2 Outgoing interface list GigabitEthernet 8 0 1145 ...
Page 1146: ...1146 ...
Page 1156: ...1156 ...
Page 1166: ...1166 ...
Page 1180: ...1180 ...
Page 1258: ...1258 ...
Page 1272: ...1272 ...
Page 1394: ...1394 ...
Page 1400: ...1400 ...
Page 1410: ...1410 ...
Page 1424: ...1424 ...
Page 1444: ...1444 ...
Page 1468: ...Version 8 3 8 0 Introduced on the S4810 1468 ...
Page 1470: ...1470 ...