Figure 33: FS7500 Controller Network Interface Ports
Table 13: Controller Interface Port Functions
Ethernet Port Numbers
Function
Comments
eth20, eth21, eth22, eth23
Left port pairs in upper callouts:
Private internal
subnet
Allows internal communication between the two
controllers.
eth30, eth31, eth32, eth33
Right port pairs in upper callouts:
SAN network
Allows communication between the NAS cluster
and the PS Series group (SAN).
Eth30 on each node must be on the same network or
VLAN as the IPMI port on the other node. For
example:
•
Node0 Eth30 on same network as Node1 IPMI
•
Node0 IPMI on same network as Node1 Eth30
eth0, eth1, eth2, eth3
Four ports in bottom callout:
Client network
Allows access to the client network (workstations,
PCs, shares).
See
NAS Service Network Requirements and Recommendations on page 51
Network Connection Requirements and Recommendations
At a minimum, you can connect all the network ports in an EqualLogic FS7500 to the same physical switch.
However, this configuration is appropriate only for demonstration or testing purposes because the network switch
is a single point of failure. Dell recommends that you use a highly-available network switch configuration for the
client, SAN, and internal network connections.
38
EqualLogic FS7500 Installation and Setup
4 Network Cable Connections