NOTE:
Remove the screws in the order of the callout numbers [1,2,3,4] as indicated on the SSD heat sink.
NOTE:
Ensure not to bend the heatsink pipe while removing the heatsink from the SSD. Do not remove the heatsink by
pulling on the pipe. Carefully pry the cover from the SSD using a plastic scribe.
2. Lift the heat-sink away from the system board.
Installing the SSD heat-sink
Prerequisites
If you are replacing a component, remove the existing component before performing the installation procedure.
About this task
The figure indicates the location of the SSD heat-sink and provides a visual representation of the installation procedure.
Steps
1. Align the screws on the SSD heat-sink with the screw holes on the system board.
2. Tighten the four captive screws to secure the SSD heat-sink to the system board.