bit
(OPTIONAL) For the TCP protocol type only, enter one or a
combination of the following TCP flags:
•
ack
= acknowledgement
•
fin
= finish (no more data from the user)
•
psh
= push function
•
rst
= reset the connection
•
syn
= synchronize sequence number
•
urg
= urgent field
operator
(OPTIONAL) For TCP and UDP parameters only. Enter one of
the following logical operand:
•
eq
= equal to
•
neq
= not equal to
•
gt
= greater than
•
lt
= less than
•
range
= inclusive range of ports (you must specify two
ports for the
port
command parameter.)
Defaults
none
Command
Modes
REDIRECT-LIST
Command
History
Version 9.4(0.0)
Introduced on the MXL 10/40GbE Switch IO Module.
Version 8.4.2.1
Introduced on the C-Series and S-Series.
Version 8.4.2.0
Introduced on the E-Series TeraScale.
Version 7.5.1.0
Introduced on the E-Series ExaScale.
redirect
Configure a rule for the redirect list.
Syntax
redirect {
ip-address
|
slot/port
} {
ip-protocol-number
|
protocol-type
[
bit
]} {
source mask
| any | host
ip-address
}
{
destination mask
| any | host
ip-address
} [
operator
]
To remove this filter, use one of the following:
• Use the
no seq sequence-number
command if you know the filter’s
sequence number.
• You can also use the
no redirect {
ip-address
|
slot/port
} {
ip-
protocol-number
[
bit
] |
protocol-type
} {
source mask
| any |
Policy-based Routing (PBR)
1007