variable
Enter the MIB object to monitor. The variable must be in the
SNMP OID format; for example, 1.3.6.1.2.1.1.3. The object
type must be a 32-bit integer.
interval
Time, in seconds, the alarm monitors the MIB variables; this
is the alarmSampleType in the RMON alarm table. The range
is from 5 to 3600 seconds.
delta
Enter the keyword
delta
to test the change between MIB
variables. This is the alarmSampleType in the RMON alarm
table.
absolute
Enter the keyword
absolute
to test each MIB variable
directly. This is the alarmSampleType in the RMON alarm
table.
rising-
threshold
value
event-number
Enter the keywords
rising-threshold
then the value (32
bit) the rising-threshold alarm is either triggered or reset.
Then enter the event-number to trigger when the rising
threshold exceeds its limit. This value is the same as the
alarmRisingEventIndex or alarmTable of the RMON MIB. If
there is no corresponding rising-threshold event, the value is
zero.
falling-
threshold
value
event-number
Enter the keywords
falling-threshold
then the value (32
bit) the falling-threshold alarm is either triggered or reset.
Then enter the event-number to trigger when the falling
threshold exceeds its limit. This value is the same as the
alarmFallingEventIndex or the alarmTable of the RMON MIB.
If there is no corresponding falling-threshold event, the value
is zero.
owner
string
(OPTIONAL) Enter the keyword
owner
then the owner name
to specify an owner for the alarm. This is the alarmOwner
object in the alarmTable of the RMON MIB.
Defaults
owner
Command
Modes
CONFIGURATION
Command
History
Version 8.3.16.1
Introduced on the MXL 10/40GbE Switch IO Module.
rmon collection history
Enable the RMON MIB history group of statistics collection on an interface.
Syntax
rmon collection history {controlEntry
integer
} [owner
name
]
[buckets
number
] [interval
seconds
]
Remote Monitoring (RMON)
1131