sflow extended-switch enable
Enable packing information on a switch only.
Syntax
sflow extended-switch enable
To disable packing information, use the
no sflow extended-switch [enable]
command.
Parameters
enable
Enter the keyword
enable
to enable global extended
information.
Defaults
Disabled.
Command
Modes
CONFIGURATION
Command
History
Version 8.3.16.1
Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
The Dell Networking OS version 7.8.1.0 and later enhances the sflow
implementation for real time traffic analysis to provide extended gateway
information in cases where the destination IP addresses are learned by different
routing protocols and for cases where the destination is reachable over ECMP.
Related
Commands
show sflow
— displays the sFlow configuration.
sflow polling-interval (Global)
Set the sFlow polling interval at a global level.
Syntax
sflow polling-interval
interval value
To return to the default, use the
no sflow polling-interval
interval
command.
Parameters
interval value
Enter the interval value in seconds. The range is from 15 to
86400 seconds. The default is
20 seconds
.
Defaults
20 seconds
Command
Modes
CONFIGURATION
Command
History
Version 8.3.16.1
Introduced on the MXL 10/40GbE Switch IO Module.
Usage
Information
The polling interval for an interface is the maximum number of seconds between
successive samples of counters sent to the collector. This command changes the
sFlow
1211