26
Getting Started Guide
Figure 1-10. AC and DC Power Connection to an N1548 Switch
Booting the Switch
When the power is turned on with the local terminal already connected,
the switch goes through a power-on self-test (POST). POST runs every time
the switch is initialized and checks hardware components to determine if the
switch is operational before completely booting. If POST detects a critical
problem, the program flow stops. If POST passes successfully, valid firmware
is loaded into RAM. POST messages are displayed on the terminal and
indicate test success or failure. The boot process runs for approximately
60 seconds.
The
Boot
menu is automatically invoked after the first part of the POST is
completed. To enter the
Boot
menu, select 2 from the menu when prompted.
From the
Boot
menu, you can perform configuration tasks such as resetting
the system to factory defaults, activating the backup image, or recovering
a password. For more information about the
Boot
menu functions, see the
CLI Reference Guide
.
To DC Power Source (Optional)
To AC Power Source