PowerConnect B-DCX-4S Backbone Hardware Reference Manual
61
53-1001808-01
RRP: Blower assembly
5
Time and items required
The replacement procedure for each blower assembly takes less than 5 minutes. The following
items are required for the blower assembly replacement:
•
Replacement blower assembly
•
Phillips #2 screwdriver
Removing a blower assembly
1. Before removing a blower assembly, verify that the other blower assembly is functioning
correctly. The power LEDs should be steady green.
2. Use the screwdriver to loosen the captive screws at the left and right of the blower assembly
(Figure 27)
.
3. Grasp the handle and pull, sliding the blower assembly from the chassis and supporting the
blower assembly from beneath as you remove it.
FIGURE 27
RRP: Blower assembly
‘