PowerConnect B-MLXe Hardware Installation Guide
103
53-1002111-01
Managing the device
5
right fan tray (fan 1): Status = OK, Speed = MED-HI (90%)
right fan tray (fan 2): Status = OK, Speed = MED-HI (90%)
--- TEMPERATURE READINGS ---
Active Mgmt Module: 36.500C 49.625C
Standby Mgmt Module: 36.250C 51.0C
SNM1: 37.0C
SNM2: 38.0C
SNM3: not present
LP1 Sensor1: 41.5C
LP1 Sensor2: 50.625C
LP4 Sensor1: 39.0C
LP4 Sensor2: 49.250C
LP4 Sensor3: UNUSED
LP4 Sensor4: 38.5C
LP4 Sensor5: 47.750C
LP4 Sensor6: UNUSED
Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds
The output displays the following information.
TABLE 19
show chassis command output
This field...
Displays...
Powers
Power
<num>, <part num>
The Power
<num>
is the power supply number as positioned in the device. The
number of power supplies are as follows:
4-slot devices: 1 – 3
8-slot devices: 1 – 4
16-slot devices: 1 – 8
The
<part num>
is the part number of the power supply purchased. This
applies to AC power supplies.
Power
<status>
Indicates whether an AC power supply is installed in the specified power supply
slot and the status of the power supply, which can be one of the following:
•
Installed (Shutdown)-The power supply has shut down. A power supply will
shut down due to flapping, or if a shut down is enabled manually using the
power-off power-supply command. Refer to
“Enabling a power supply
shutdown”
on page 165.
•
Installed (OK) – The power supply is functioning properly and supplying
power to the device and installed modules.
•
Failed – The power supply is not functioning and is not supplying power to
the device and installed modules.
•
not present – There is no power supply installed in the slot.
•
Installed (Failed or Disconnected) - The power supply is not functioning, or
the power supply is not connected to the device and installed modules.
Total power budget for device
The sum of all power (in watts), used by all power supplies currently functioning
in the device.
Total power used by system core
The total power used by the management modules, switch fabric modules, and
fans. Each component consumes different amounts of power.
Total power used by LPs
The total power used by the interface modules. Each module type consumes
different amounts of power.
Total power available
The total power budget for the device minus the total power used by the system
core and the installed interface modules.
Slot Power-On Priority
The configured power-on priority of each interface module.
Summary of Contents for PowerConnect B - MLXe 16
Page 1: ...53 1002111 01 02 November 2010 PowerConnect B MLXe Hardware Installation Guide ...
Page 194: ...182 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Power cords 8 ...
Page 198: ...186 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Russia A ...
Page 212: ...200 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Dangers B ...