PowerConnect B-MLXe Hardware Installation Guide
129
53-1002111-01
Important software upgrade considerations
6
08/06/2008 03:42:12 705 $$sshdsspub.key
07/30/2008 10:21:56 1,712 $$sslcert.key
08/09/2008 09:03:14 980,769 IMF.cfg
08/10/2008 12:49:09 981,804 IMF1.cfg
08/16/1908 06:38:47 2,663,857 ___mbridge
08/15/1908 09:21:34 2,663,857 ___mbridge.old <<<<<<<<<<<<<
08/20/1908 12:38:45 123 boot-parameter
08/21/1908 12:12:27 524,288 lp-monitor-0
08/27/1908 11:25:18 3,335,554 lp-primary-0
08/31/1908 06:13:15 3,304,730 lp-secondary-0
08/17/1908 14:10:29 422,393 monitor
08/27/1908 11:25:48 6,530,021 primary
08/31/1908 06:13:43 6,244,777 secondary
08/31/1908 06:53:40 981,549 startup-config
15 File(s) 28,636,142 bytes
0 Dir(s) 2,097,152 bytes free
If necessary, you can delete the mbridge.old file to increase the available memory. Though unlikely,
you may have to delete additional files for the upgrade to succeed. Contact Dell technical support
before removing additional files.
PowerConnect# delete___mbridge.old
NOTE
The file name delete___mbridge.old must contain
three
underscores.
After deleting the mbridge.old file, enter to dir command to verify that the mbridge.old file has been
removed, and that there are enough bytes free to begin the upgrade.
PowerConnect# dir <<<<<
Directory of /flash/
08/31/1908 13:26:14 3 $$snmp_boots
08/06/2008 03:42:12 705 $$sshdsspub.key
07/30/2008 10:21:56 1,712 $$sslcert.key
08/09/2008 09:03:14 980,769 IMF.cfg
08/10/2008 12:49:09 981,804 IMF1.cfg
08/16/1908 06:38:47 2,663,857 ___mbridge
<<<<<<<<<<<<<<<<<<<<<mbridge.old file is removed
08/20/1908 12:38:45 123 boot-parameter
08/21/1908 12:12:27 524,288 lp-monitor-0
08/27/1908 11:25:18 3,335,554 lp-primary-0
08/31/1908 06:13:15 3,304,730 lp-secondary-0
08/17/1908 14:10:29 422,393 monitor
08/27/1908 11:25:48 6,530,021 primary
08/31/1908 06:13:43 6,244,777 secondary
08/31/1908 06:53:40 981,549 startup-config
14 File(s) 25,972,285 bytes
0 Dir(s) 4,718,592 bytes free
You must also delete the mbridge.old file from the redundant management module, if one is
installed. To access the redundant management module, enter the switchover command to make it
the active management module.
Summary of Contents for PowerConnect B - MLXe 16
Page 1: ...53 1002111 01 02 November 2010 PowerConnect B MLXe Hardware Installation Guide ...
Page 194: ...182 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Power cords 8 ...
Page 198: ...186 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Russia A ...
Page 212: ...200 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Dangers B ...