138
PowerConnect B-MLXe Hardware Installation Guide
53-1002111-01
Displaying image versions
6
Performing a coherence check without a reload
Enter the reload-check command to perform a coherence check
without
performing a reload, as
shown in the following example:
PowerConnect# reload-check
Checking for coherence...
Warning: The new LP PBIF-8X10 FPGA will not be compatible with the new LP 3
application.
Warning: The new LP XPP-8X10 FPGA will not be compatible with the new LP 3
application.
Done.
PowerConnect#
If interface modules are in interactive mode, or the system is unable to communicate with the
interface modules, the system sends the following warning message.
Can’t check LP for coherence
.
Error messages generated by the coherence check
The following error messages are generated if a coherence check fails:
Warning: Image coherence check skipped due to insufficient info: Invalid active LP
# flash images in Primary/Secondary.
Warning: Image coherence check skipped due to insufficient info: Invalid active MP
flash images in Primary/Secondary.
Warning: Image coherence ckeck skipped due to insufficient info: MP/LP not booting
from flash.
Warning: Image coherence check skipped due to failure to communiate with LP.
If interface modules are in interactive mode, or the system is unable to communicate with the
interface modules, the system sends the following warning message.
Can’t check LP for coherence
.
Displaying image versions
The following sections describe how to display software image version information for
PowerConnect B-MLXe routers, using the show flash or show version commands.
Using the show flash command
You can display the images stored in flash memory using the show flash command.
NOTE
This example is for illustration only and may not reflect current image version information.
Output from the show flash command resembles this example.
PowerConnect# show flash
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Summary of Contents for PowerConnect B - MLXe 16
Page 1: ...53 1002111 01 02 November 2010 PowerConnect B MLXe Hardware Installation Guide ...
Page 194: ...182 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Power cords 8 ...
Page 198: ...186 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Russia A ...
Page 212: ...200 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Dangers B ...