PowerConnect B-MLXe Hardware Installation Guide
145
53-1002111-01
Configurations conditions specific to NI-MLX-1Gx48-T modules
6
LP Slot 4 uptime is 58 seconds
==========================================================================
SL 6: NI-MLX-10Gx4 4-port 10GbE Module (Serial #: SA12090950, Part #: 35600-202D)
Boot: Version 5.1.0T175 Copyright (c) 1996-2009 Brocade Communications Systems,
Inc.
Compiled on Aug 11 2010 at 14:07:20 labeled as xmlprm05100
(492544 bytes) from boot flash
Monitor: Version 5.1.0T175 Copyright(c)1996-2009 Brocade Communications Systems,
Inc.
Compiled on Aug 11 2010 at 14:07:42 labeled as xmlb05100
(493244 bytes) from code flash
IronWare: Version 5.1.0T177 Copyright(c)1996-2009 Brocade Communications Systems,
Inc.
Compiled on Sep 16 2010 at 17:55:24 labeled as xmlp05100
(4950936 bytes) from Primary
FPGA versions:
Valid PBIF Version = 3.22, Build Time = 2/5/2010 14:43:00
Valid XPP Version = 6.04, Build Time = 2/3/2010 14:39:00
Valid XGMAC Version = 0.13, Build Time = 2/3/2010 14:42:00
X10G2MAC 0
X10G2MAC 1
666 MHz MPC 8541 (version 8020/0020) 333 MHz bus
512 KB Boot Flash (AM29LV040B), 16 MB Code Flash (MT28F640J3)
512 MB DRAM, 8 KB SRAM, 286331153 Bytes BRAM
PPCR0: 768K entries CAM, 8192K PRAM, 2048K AGE RAM
PPCR1: 768K entries CAM, 8192K PRAM, 2048K AGE RAM
LP Slot 6 uptime is 59 seconds
==========================================================================
All show version done
Configurations conditions specific to NI-MLX-1Gx48-T modules
ifIndex allocation
The SNMP Management Information Base (MIB) uses the Interface Index (ifIndex) to assign a
unique value to each port on a module or slot.
•
If you will be installing the NI-MLX-1Gx48-T module on your device, you must configure the
maximum ifIndex per module to 64. You must change the ifIndex allocation before installing
the NI-MLX-1Gx48-T module; otherwise, the module remains in the Offline state.
•
If you have a new device (no previous software installed), and you will be installing an
NI-MLX-1Gx48-T module, you must configure the maximum ifIndex per module to 64;
otherwise, the module remains in the Offline state.
•
If you have a new device (no previous software installed), and will not be installing an
NI-MLX-1Gx48-T module, it is recommended that you configure the maximum ifIndex per
module to 64 to avoid future ifIndex problems if you decide to install an NI-MLX-1Gx48-T
module in the future.
Port MAC address change
The MAC address assigned to each port may change to accommodate a greater number of ports
per module. The MAC address ports allocated for each module has increased from 20 to 48.
Summary of Contents for PowerConnect B - MLXe 16
Page 1: ...53 1002111 01 02 November 2010 PowerConnect B MLXe Hardware Installation Guide ...
Page 194: ...182 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Power cords 8 ...
Page 198: ...186 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Russia A ...
Page 212: ...200 PowerConnect B MLXe Hardware Installation Guide 53 1002111 01 Dangers B ...