voice vlan cos
Use the
voice vlan cos
Global Configuration mode command to set the OUI
Voice VLAN Class of Service (CoS). Use the
no
form of this command to
restore the default configuration..
Syntax
voice vlan cos
cos
[remark]
no voice vlan cos
Parameters
•
cos
—Specifies the voice VLAN Class of Service. (Range: 0–7)
•
remark
—Specifies that the L2 User Priority is remarked.
Default Configuration
The default CoS value is 6.
The L2 User Priority is not remarked.
Command Mode
Global Configuration mode
User Guidelines
Example
The following example sets the OUI Voice VLAN CoS to 6.
Console(config)#
voice vlan cos
7
voice vlan aging-timeout
Use the
voice vlan aging-timeout
Global Configuration mode command to
set the OUI Voice VLAN aging timeout interval. Use the
no
form of this
command to restore the default configuation.