Dell PowerConnect W AirWave 7.1
| User Guide
Configuring and Using Device Groups in AWMS |
89
14. To configure Symbol or Intel-specific settings, locate the
Symbol/Intel
section and adjust these settings as
required.
Table 48
describes the settings and default values of this section.
15. To configure settings specific to Dell PowerConnect W, locate the
Dell PowerConnect W
section and adjust
these settings as required. Table 49 describes the settings and default values of this section.
SNMP Version
2c
Drop-down menu specifies the version of SNMP used by AWMS to communicate to the
AP.
Table 47
HP ProCurve 420
Fields and Default Values
Setting
Default Description
Note: DST Start Month, Start Day, End Month and End Day are only visible if Daylight Saving Time is enabled in the NTP section of
the Groups > Basic configuration page.
Table 48
Symbol/Intel
Fields and Default Values
Setting
Default
Description
SNMP Version
2c
Drop-down menu specifies the version of SNMP used by AWMS to communicate to the
device.
Symbol/Intel Client
Inactivity Timeout
(3-600 min)
3
Sets the minutes of inactivity after which a client associated to an Intel or Symbol AP will
be considered "inactive." A lower value typically provides a more accurate representation
of current WLAN usage.
NOTE: For other APs, AWMS has more precise methods to determine when inactive clients
are no longer associated to an AP.
Symbol Controller
CLI Communication
Telnet
Select which connection type is to support the command-line interface (CLI) connection.
The options are Telnet and secure shell (SSH). This is supported for WS5100 and RFS7000
devices only.
Web Config
Interface
Yes
Enables or disables the http/https configuration page for the Symbol 4131 and Intel 2011
devices.
Table 49
Dell PowerConnect W
Fields and Default Values
Setting
Default Description
SNMP Version
2c
Drop-down menu specifies the version of SNMP used by AWMS to communicate to the AP.
Offload Dell
PowerConnect W
WMS database
No
Configures commands previously documented in the
Dell PowerConnect W AirWave Best
Practices Guide
. See the current
Best Practices
guide for more information about this
feature. When enabled, this feature allows AWMS to display historical information for WLAN
switches.
Changing the setting to Yes pushes commands via SSH to all WLAN switches in Monitor Only
mode without rebooting the controller. The command can be pushed to controllers in manage
mode (also without rebooting the controller) if the Allow WMS Offload setting on the AWMS
configuration page is changed to Yes.
Dell PowerConnect
W GUI Config
Yes
Enables or disables AWMS support for the Dell PowerConnect W configuration interface.
This setting relates to the Device Setup > Dell PowerConnect W Configuration page and all
related operations. For additional information, refer to the
Dell PowerConnect W
Configuration Guide
.
Summary of Contents for PowerConnect W Airwave 7.1
Page 1: ...Dell PowerConnect W AirWave Version 7 1 User Guide ...
Page 10: ...10 Dell PowerConnect W AirWave 7 1 User Guide ...
Page 30: ...30 Installing AWMS Dell PowerConnect W AirWave 7 1 User Guide ...
Page 194: ...194 Creating and Using Templates Dell PowerConnect W AirWave 7 1 User Guide ...
Page 260: ...260 Performing Daily Administration in AWMS Dell PowerConnect W AirWave 7 1 User Guide ...
Page 294: ...294 Creating Running and Emailing Reports Dell PowerConnect W AirWave 7 1 User Guide ...
Page 302: ...302 Using the AWMS Helpdesk Dell PowerConnect W AirWave 7 1 User Guide ...
Page 304: ...304 Package Management for AWMS Dell PowerConnect W AirWave 7 1 User Guide ...
Page 308: ...308 Third Party Security Integration for AWMS Dell PowerConnect W AirWave 7 1 User Guide ...
Page 314: ...314 Access Point Notes Dell PowerConnect W AirWave 7 1 User Guide ...
Page 316: ...316 Initiating a Support Connection Dell PowerConnect W AirWave 7 1 User Guide ...
Page 318: ...318 Cisco Clean Access Integration Perfigo Dell PowerConnect W AirWave 7 1 User Guide ...
Page 330: ...330 Third Party Copyright Information Dell PowerConnect W AirWave 7 1 User Guide ...
Page 334: ...334 Index Dell PowerConnect W AirWave 7 1 User Guide ...