background image

 

Dell PowerConnect W-AP100 

Series Access Point

Installation Guide

www.Dell.com

Dell PowerConnect W-AP100 Series Access Point | Installation Guide
Part Number 0511056-01 | February 2012

Contacting Support

Web Site Support

Main Site

dell.com 

Support Site

support.dell.com 

Dell Documentation

support.dell.com/manuals

Copyright

© 2012 Aruba Networks, Inc. Aruba Networks trademarks include 

, Aruba Networks

®

Aruba Wireless Networks

®

, the registered Aruba the Mobile Edge Company logo, and Aruba Mobility 

Management System

®

. Dell™, the DELL™ logo, and PowerConnect™ are trademarks of Dell Inc.

All rights reserved. Specifications in this manual are subject to change without notice.

Originated in the USA. All other trademarks are the property of their respective owners.

Open Source Code

Certain Aruba products include Open Source software code developed by third parties, including software code 
subject to the GNU General Public License (GPL), GNU Lesser General Public License (LGPL), or other Open 
Source Licenses. The Open Source code used can be found at this site:

http://www.arubanetworks.com/open_source

Legal Notice

The use of Aruba Networks, Inc. switching platforms and software, by all individuals or corporations, to terminate 
other vendors’ VPN client devices constitutes complete acceptance of liability by that individual or corporation for 
this action and indemnifies, in full, Aruba Networks, Inc. from any and all legal actions that might be taken against 
it with respect to infringement of copyright on behalf of those vendors.

Connecting Required Cables

Install cables in accordance with all applicable local and national regulations and 
practices.

Ethernet Ports

The RJ45 Ethernet port (ENET) supports 10/100/1000Base-T auto-sensing MDI/
MDX connections. Use these ports to connect the AP to a twisted pair Ethernet LAN 
segment or directly to a Dell PowerConnect W Controller. Use a 4- or 8-conductor, 
Category 5 UTP cable up to 100 m (325 feet) long.

The 10/100/1000 Mbps Ethernet port is on the back of the AP. The port has an RJ-45 
female connector with the pin-outs shown in 

Figure 5

.

Figure 5  

Gigabit Ethernet Port Pin-Out

Serial Console Port

The serial console port (Console) allows you to connect the AP to a serial terminal or 
a laptop for direct local management. This port is an RJ-45 female connector with the 
pinouts described in 

Figure 6

. Connect this port in one of the following ways:

Connect it directly to a terminal or terminal server using an Ethernet cable.

Use a modular adapter to convert the RJ-45 (female) connector on the AP to a 
DB-9 (male) connector, and connect the adapter to a laptop using an RS-232 
cable. See 

Figure 7

 for connector details of the adapter.

Figure 6  

Serial Port Pin-Out

Figure 7  

RJ-45 (Female) to DB-9 (Male) Modular Adapter Conversion

Power Connection

The W-AP100 Series has a single 12V DC power jack socket to support powering 
through an AC-to-DC power adapter.

Verifying Post-Installation Connectivity

The integrated LEDs on the AP can be used to verify that the AP is receiving power 
and initializing successfully (see 

Table 1

). Refer to the 

Dell PowerConnect W-Series 

ArubaOS Quick Start Guide

 for further details on verifying post-installation network 

connectivity.

Configuring the W-AP100 Series

AP Provisioning/Reprovisioning

Provisioning parameters are unique to each AP. These local AP parameters are 
initially configured on the controller which are then pushed out to the AP and stored 
on the AP itself. It is recommended that provisioning settings be configured via the 
ArubaOS Web UI only. For more information, see the 

Dell PowerConnect W-Series 

ArubaOS User Guide

 at 

support.dell.com/manuals.

AP Configuration

Configuration parameters are network or controller specific and are configured and 
stored on the controller. Network configuration settings are pushed out to the AP(s) 
but remain stored on the controller.

Configuration settings can be configured via the ArubaOS Web UI or ArubaOS CLI. 
For more information, see the 

Dell PowerConnect W-Series ArubaOS User Guide

 or 

Dell PowerConnect W-Series ArubaOS Command Line Reference Guide 

at 

support.dell.com/manuals.

Product Specifications

Electrical

Ethernet:

1 x 10/100/1000Base-T auto-sensing Ethernet RJ-45 Interfaces

MDI/MDX

IEEE 802.3 (10Base-T), IEEE 802.3u (100Base-T),
IEEE 802.3ab (1000Base-T)

Power over Ethernet (IEEE 802.3af compliant), 48V DC/350mA 
(see 

Figure 5

 for pin configuration)

Power:

12 VDC power interface, supports powering through an AC-to-DC power 
adapter

For additional specifications on this product, please refer to the data sheet. The data 
sheet can be found at 

dell.com

.

Proper Disposal of Dell Equipment

For the most current information about Global Environmental Compliance and Dell 
products, see our website at 

dell.com

.

Waste of Electrical and Electronic Equipment

Dell products at end of life are subject to separate collection and 
treatment in the EU Member States, Norway, and Switzerland and 
therefore are marked with the symbol shown at the left (crossed-out 
wheelie bin). The treatment applied at end of life of these products 
in these countries shall comply with the applicable national laws of 
countries implementing Directive 2002/96EC on Waste of Electrical 
and Electronic Equipment (WEEE).

European Union RoHS

Dell products also comply with the EU Restriction of 
Hazardous Substances Directive 2002/95/EC (RoHS). EU 
RoHS restricts the use of specific hazardous materials in the 

manufacture of electrical and electronic equipment. Specifically, restricted materials 
under the RoHS Directive are Lead (including Solder used in printed circuit 
assemblies), Cadmium, Mercury, Hexavalent Chromium, and Bromine. Some Dell 
products are subject to the exemptions listed in RoHS Directive Annex 7 (Lead in 
solder used in printed circuit assemblies). Products and packaging will be marked 
with the “RoHS” label shown at the left indicating conformance to this Directive.

China RoHS

Dell products also comply with China environmental declaration 
requirements and are labeled with the “EFUP 10” label shown at the 
left.

Safety and Regulatory Compliance

Dell provides a multi-language document that contains country-specific restrictions 
and additional safety and regulatory information for all Dell access points. This 
document can be viewed or downloaded from 

support.dell.com 

EMC Compliance and Warning Statement

IEC 60601-1-2: 2007 

EN 60601-1-2: 2007 

The W-AP105 has been tested and found to comply with the limits of the standard 
for medical devices, IEC 60601-1-2:2007. The unit also complies with the 
requirements of EN 60601-1-2:2007, providing the presumption of compliance to the 
European Union’s Medical Device Directive 2007/47/EC. The limits are designed to 
provide reasonable protection against harmful interference in a typical medical 
installation. This equipment generates, uses and can radiate radio frequency energy, 
and, if not installed and used in accordance with the manufacturer’s instructions may 
cause harmful interference to other devices in the vicinity. However, there is no 
guarantee that interference will not occur in a particular installation. If this 
equipment causes interference with other devices, which may be determined by 
turning the equipment off and on, the user is encouraged to try and correct the 
interference by one or more of the following measures:

Reorient or relocate the device receiving the interference.

Increase the separation between the equipment.

Connect the equipment into an outlet on a circuit different from that to which 
the other device(s) are connected.

Consult the manufacturer or field service technician for help.

The Model W-AP105 do not have an Applied Part as defined in IEC 60601-1. The 
protection against electric shock is Class ll. 

Device is not protected against ingress of liquids and has a protection class of IPX0 as 
defined by IEC 60601-1 and IEC 60529. Equipment not suitable for use in the 
presence of flammable mixtures.

The unit is considered “Continuous Operation” equipment as defined by IEC 60601-1. 

Power Consumption – 48 VDC 802.3af power over Ethernet or 12VDC, 1.25A for 
external AC supplied power (adapter sold separately); Maximum power consumption 
– 12.5W. 

Mechanical Dimensions: 132mm x 135mm x 45mm; 300g.

Environmental: Operating Temp: 0° C to +50° C (+32° F to +122° F); Humidity: 5 
to 95% non-condensing. Storage Temp: -40° CS to +70° C (-40°F to +158°F).

 

Note:  If both POE and DC power are available, the AP uses POE even when there is 
not enough POE voltage available to power the AP.

Table 1  

W-AP100 Series LED Meanings 

LED

Color/State

Meaning

PWR

Off

No power to AP

Green flashing

System initializing

Red steady

System failed to initialize, contact TAC

Green steady

Power on, device ready

ENET
(10/100/1000 Mbps)

Off

No link

Green on

1000 Mbps link

Amber on

10/100 Mbps link

Green flashing

Ethernet link activity

11A/N

Off

5 GHz radio is disabled

Amber 

5 GHz radio enabled in WLAN mode

Green

5 GHz radio enabled in 11n mode

Green flashing

5 GHz Air Monitor or RF Protect mode

11B/G/N

Off

2.4 GHz radio disabled

Amber 

2.4 GHz radio enabled in WLAN mode

Green

2.4 GHz radio enabled in 11n mode

Green flashing

2.4 GHz Air Monitor or RF Protect mode

1000Base-T Gigabit 

Ethernet Port

RJ-45 Female
Pin-Out

Signal Name

1
2
3
4
5
6
7
8

BI_DC+
BI_DC-

BI_DD+
BI_DD-

BI_DA+
BI_DA-
BI_DB+

BI_DB-

Function

Bi-directional pair +C
Bi-directional pair -C

Bi-directional pair +D
Bi-directional pair -D

Bi-directional pair +A
Bi-directional pair -A
Bi-directional pair +B

Bi-directional pair -B 

   

Serial

Console Port

1

2

3

4

5

6

7

8

TxD

GND

RxD

RJ-45 Female

Pin-Out

Direction

Input

Output

GND

3

4

5

2

5

6

3

RJ-45

DB-9

Internal

Connections

TxD

GND

RxD

1

2

3

4

5

6

7

8

TxD

GND

RxD

RJ-45 Female

Pin-Out

Direction

Input

Output

DB-9 Male

Pin-Out

TxD

RxD

Ground

5

4

3

2

1

9

8

7

6

Direction

Input

Output

Note:  If a power adapter other than the one provided by Dell is used in the US or 
Canada, it should be cULus (NRTL) Listed, with an output rated 12 VDC, minimum 
1.25A, marked “LPS” or “Class 2,” and suitable for plugging into a standard power 
receptacle in the US and Canada.

10

Caution:  RF Radiation Exposure Statement: This equipment complies with FCC RF 
radiation exposure limits. This equipment should be installed and operated with a 
minimum distance of 13.78 inches (35 cm) between the radiator and your body for 2.4 
GHz and 5 GHz operations. This transmitter must not be co-located or operating in 
conjunction with any other antenna or transmitter. When operated in the 5.15 to 5.25 
GHz frequency range, this device is restricted to indoor use to reduce the potential for 
harmful interference with co-channel Mobile Satellite Systems.

᳝↦᳝ᆇ⠽䋼ໄᯢ

Hazardous Materials Declaration

᳝↦᳝ᆇ⠽䋼៪ܗ㋴

(Hazardous Substance) 

䚼ӊৡ⿄

(Parts) 

3E

+J

&G

݁Ӌ䫀

&U

໮⒈㘨㣃

3%%

໮⒈Ѡ㣃䝮

3%'(

⬉䏃ᵓ

(

PCA Boards)

h

ƻ

ƻ

ƻ

ƻ

ƻ

ᴎẄ㒘ӊ

(

Mechanical Sub-Assemblies)

h

ƻ

ƻ

ƻ

ƻ

ƻ


ƻ˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼೼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ৿䞣ഛ೼

SJ/T11363-2006

ᷛޚ㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽ

Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is 
below the relevant threshold of the SJ/T11363-2006 standard.


h˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼㟇ᇥ೼䆹䚼ӊⱘᶤϔഛ䋼ᴤ᭭Ёⱘ৿䞣䍙ߎ6-7ᷛޚ㾘ᅮⱘ䰤䞣㽕∖DŽ

Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials 
in the parts is above the relevant threshold of the SJ/T11363-2006 standard. 

ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ৿䖭ѯ⠽䋼DŽ

This table shows where these substances may be found in the supply chain of electronic information 

products, as of the date of sale of the enclosed product.   

ℸᷛᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳᷛᖫᶤѯ䳊䚼ӊӮ᳝ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ
՟བ⬉∴ऩܗ῵ഫ䌈೼݊ѻકϞ
ℸ⦃ֱՓ⫼ᳳ䰤া䗖⫼Ѣѻકᰃ೼ѻક᠟ݠЁ᠔㾘ᅮⱘᴵӊϟᎹ԰

The Environment- Friendly Use Period (EFUP) for all enclosed products and their parts are 
per the symbol shown here. The Environment- Friendly Use Period is valid only when the 
product is operated under the conditions defined in the product manual. 

200202320G

TRA

REGISTERED No:

DEALER No:

DA0039425/10

0019614/09

Reviews: