14. To convert the bottom mounting ear to rack right ear:
a) Remove the screws securing the ear cover to be replaced by the cartridge, and remove the cover.
b) Align the tabs on the cartridge with the slots in the ear, and lower the cartridge until firmly seated.
When properly seated, the screw holes on the other end of the cartridge align with the screw holes on the ear.
c) Attach the two screws to secure the cartridge to the ear.
Figure 92. Converting the Bottom Mounting Ear to Right Rack Ear
1. mounting ear
2. cartridge
3. screws (2)
4. tabs on cartridge (2)
The mounting ears are converted to rack ears.
15. Attach the rack ears to the chassis. See
Installing The Mounting Ears
.
16. Reinstall the following:
a) control panel
b) cooling-fan assembly
c) cooling shroud
d) PCIe cage door
17. Close the system.
18. Reinstall the following:
a) blower module bay
b) blower modules
c) hard drives
d) server modules
19. Reconnect the enclosure to its electrical outlet and turn the enclosure on, including any attached peripherals.
20. Turn on the server modules using the operating system commands or the CMC.
21. If applicable, install the front bezel.
139