126
About Your System
FBD training
error: The
following branch
has been disabled:
Branch
x
.
The specified branch
(channel pair) contains
DIMMs that are
incompatible with each
other.
Ensure that only Dell
qualified memory is used.
Dell recommends
purchasing memory upgrade
kits directly from
dell.com
or your Dell sales agent to
ensure compatibility.
Gate A20 failure.
Faulty keyboard controller
(faulty blade board).
See "Getting Help" on
page 361.
General Failure.
Operating system
corrupted or improperly
installed.
Reinstall the operating
system.
HyperTransport
error caused a
system reset.
Please check the
system event log
for details.
HyperTransport error.
See "Getting Help" on
page 361.
Invalid
flexAddress for
bus
,
device
,
function
.
FlexAddress (virtual
MAC) is not supported on
the specified device.
Information only.
Keyboard
controller
failure.
Faulty keyboard controller
(faulty blade board).
See "Getting Help" on
page 361.
Keyboard failure.
Loose or improperly
connected keyboard cable.
Ensure that the keyboard is
properly connected. If the
problem persists, replace the
keyboard.
Table 1-27. Blade Messages
(continued)
Message
Causes
Corrective Actions
Summary of Contents for PowerEdge M620
Page 1: ...Dell PowerEdge Modular Systems Hardware Owner s Manual ...
Page 60: ...60 About Your System Figure 1 24 Example of PowerEdge M610x Port Mapping of Blade 2 ...
Page 68: ...68 About Your System Figure 1 26 Example of Half Height Blade Port Mapping ...
Page 136: ...136 About Your System ...
Page 286: ...286 Installing Blade Components ...
Page 308: ...308 Installing Enclosure Components ...
Page 330: ...330 Running System Diagnostics ...
Page 360: ...360 System Board Information ...
Page 362: ...362 Getting Help ...
Page 368: ...Index 368 V video controller installing 273 ...