Error Code
Message Information
Details
The memory may not be seated correctly, misconfigured, or
has failed.
Action
Check the memory configuration. Re-seat the memory
modules. If the issue persists, see
Getting Help
.
MEM7002
Message
A hardware mismatch detected for memory riser.
LCD Message
Memory riser mismatch detected. Check memory riser.
Details
Memory riser is installed incorrectly, or failed.
Action
Check that the memory riser is installed correctly. If the issue
persists, see
Getting Help
.
MEM8000
Message
Correctable memory error logging disabled for a memory
device at location <
location
>.
LCD Message
SBE log disabled on <
location
>. Re-seat memory.
Details
Errors are being corrected but no longer logged.
Action
Review system logs for memory exceptions. reinstall
memory at location <
location
>.
OSE0000
Message
A critical stop occurred during OS load.
Details
The system halted due to an exception during operating
system load or operating system initialization.
Action
Review operating system logs and system video for
additional information.
OSE0001
Message
A runtime critical stop occurred.
Details
The system halted due to an exception while the operating
system was running. This is a kernel panic or bug check
event.
Action
Review operating system logs and system video for
additional information.
OSE0004
Message
A soft shut-down initiated by platform event filter.
Details
A separate exception or status condition shutdown the
operating system. (IPMI sensor type 20h - offset 04h).
Action
Review system event log for platform events capable of
shutting the system down.
109