Error Code
Message Information
Action
1.
Remove and reinstall the power supply.
2.
Check cables and subsystem components in the system
for damage.
3.
If the issue persists, see
Getting Help
.
PSU0031
Message
Cannot communicate with power supply <
number
>.
LCD Message
Cannot communicate with PSU <
number
>. Re-seat PSU.
Details
The power supply may operate, however power supply
monitoring will be degraded. System performance may be
degraded.
Action
Remove and reinstall the power supply. If the issue persists,
see
Getting Help
.
PSU1201
Message
Power supply redundancy is lost.
Details
The power supply will try to operate in a degraded state.
System Performance and power redundancy may be
degraded or lost.
Action
Check input power. Reinstall the power supply. If the issue
persists, see
Getting Help
.
PSU1202
Message
Power supply redundancy is degraded.
Details
The power supply will try to operate in a degraded state.
System Performance and power redundancy may be
degraded or lost.
Action
Remove input power and reinstall supply at the next service
window.
PSU1203
Message
The power supplies are not redundant.
LCD Message
Lost PSU redundancy. Check PSU cables.
Details
The current power operational mode is non-redundant
because of a power supply exception, a power supply
inventory change, or a system power inventory change.
Action
Check the event log for power supply failures. Review
system configuration and power consumption.
PSU1204
Message
The power supplies are not redundant. Insufficient resources
to maintain normal operations.