Error Code
Message Information
Details
The media is being prepared or is under maintenance. If the
problem persists, reinstall the card.
Action
If unintended, reinstall the flash media.
RFM1024
Message
Removable Flash Media is offline.
Details
At boot, the Card Identification (CID) signature of the card is
different from the Non-volatile (NV) storage value or the card
is the destination of a copy operation that is in-progress.
Action
If unintended, reinstall the flash media.
RFM1026
Message
Failure detected on Removable Flash Media.
Details
An error is reported during a SD card read or write.
Action
Reinstall the flash media, if the issue persists replace the
media.
RFM1032
Message
Removable Flash Media is write protected.
Details
The card is write-protected by the physical latch on the SD
card. IDSDM cannot use a write-protected card.
Action
If unintended, remove the media and disable write
protection.
RFM1034
Message
Media not present for Removable Flash Media.
Details
The SD card is not detected or not installed.
Action
If unintended, reinstall the flash media.
RFM1201
Message
Internal Dual SD Module redundancy is lost.
LCD Message
Internal Dual SD Module redundancy is lost. Check SD Card.
Details
Either one of the SD card or both the SD cards are not
functioning properly.
Action
Replace the failed SD card.
RFM1202
Message
Internal Dual SD Module redundancy is degraded.
Details
Either one of the SD card or both the SD cards are not
functioning properly.
Action
Replace the failed SD card.
128