Error Code
Message Information
Details
FlexAddress is not implemented in one of the versions of
firmware. Please update the firmware.
Action
Check firmware versions. Update CMC 1 and CMC 2
firmware to match.
SWC5001
Message
<
name
> upgrade failed.
Action
Reboot the system and attempt the upgrade again.
TMP0100
Message
The system board <
name
> temperature is less than the lower
warning threshold.
LCD Message
System board <
name
> temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0101
Message
The system board <
name
> temperature is less than the lower
critical threshold.
LCD Message
System board <
name
> temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0102
Message
The system board <
name
> temperature is greater than the
upper warning threshold
LCD Message
System board <
name
> temperature is outside of range.
Details
Ambient air temperature is too warm or one or more fans
may have failed.
Action
The system board <
name
> temperature is outside of the
optimum range. Check the fans.
TMP0103
Message
The system board <
name
> temperature is greater than the
upper critical threshold.
LCD Message
System board <
name
> temperature is outside of range.
Details
Ambient air temperature is too warm or one or more fans
may have failed.
Action
The system board <
name
> temperature is outside of the
optimum range. Check the fans.
137