Error Code
Message Information
Action
Check the system operating environment and review event
log for fan failures.
TMP0100
Message
Disk drive bay temperature is less than the lower warning
threshold.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0104
Message
Disk drive bay temperature is less than the lower critical
threshold.
LCD Message
Disk drive bay temperature is outside of range. Check Fans.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0126
Message
Disk drive bay temperature is greater than the upper warning
threshold.
LCD Message
Disk drive bay temperature is outside of range. Check Fans.
Details
Ambient air temperature is too warm or one or more fans
may have failed.
Action
Check the system operating environment and review event
log for fan failures.
TMP0128
Message
Disk drive bay temperature is outside of the allowable range.
LCD Message
Disk drive bay temperature is outside of range. Check Fans.
Details
Ambient air temperature is too warm or cool.
Action
Check the system operating environment and review event
log for fan failures.
TMP0130
Message
The control panel temperature is less than the lower warning
threshold.
LCD Message
Control panel temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0132
Message
The control panel temperature is greater than the upper
warning threshold.
141