Error Code
Message Information
VLT0102
Message
Processor module <
name
> voltage is greater than the upper
warning threshold.
LCD Message
Processor module <
name
> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1.
Review system logs for power supply exceptions.
2.
Remove the processor module. Inspect processor
socket for bent pins.
3.
If the issue persists, see
Getting Help
.
VLT0103
Message
Processor module <
name
> voltage is greater than the upper
critical threshold.
LCD Message
Processor module <
name
> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1.
Review system logs for power supply exceptions.
2.
Remove the processor module. Inspect processor
socket for bent pins.
3.
If the issue persists, see
Getting Help
.
VLT0104
Message
Processor module <
name
> voltage is outside of the
allowable range.
LCD Message
Processor module <
name
> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the
system may power down in fail-safe mode.
Action
1.
Review system logs for power supply exceptions.
2.
Remove the processor module. Inspect processor
socket for bent pins.
3.
If the issue persists, see
Getting Help
.
143