Error Code
Message Information
CPU0803
Message
The power input for CPU <
number
> voltage regulator
module is lost.
LCD Message
Lost power input for CPU <
number
>voltage regulator
module. Re-seat module.
Details
System performance may be degraded or the system may
fail to operate.
Action
1.
Turn system off and remove input power for one
minute.
2.
Reapply input power and turn system on.
3.
Ensure the processor is seated correctly.
4.
If the issue persists, see
Getting Help
.
CPU0804
Message
The power input for CPU <
number
> voltage regulator
module is outside of range.
LCD Message
The power input for CPU <
number
> voltage regulator
module is outside of range. Re-seat module.
Details
System performance may be degraded or the system may
fail to operate.
Action
1.
Turn system off and remove input power for one
minute.
2.
Reapply input power and turn system on.
3.
Ensure the processor is seated correctly.
4.
If the issue persists, see
Getting Help
.
CPU0805
Message
The power input for CPU <
number
> voltage regulator
module is outside of range, but it is attached to the system.
Details
System performance may be degraded or the system may
fail to operate.
Action
1.
Turn system off and remove input power for one
minute.
2.
Reapply input power and turn system on.
3.
Ensure the processor is seated correctly.
4.
If the issue persists, see
Getting Help
.
CPU0806
Message
CPU <
number
> voltage regulator module is incorrectly
configured.