Error Code
Message Information
LCD Message
CPU <
number
> voltage regulator module incorrectly
configured. Check configuration.
Details
System performance may be degraded or the system may
fail to operate.
Action
Review this manual for proper configuration and installation
procedures.
CPU0816
Message
CPU <
number
> voltage regulator module is absent.
LCD Message
CPU <
number
> voltage regulator module absent. Check
module.
Details
System performance may be degraded or the system may
fail to operate.
Action
If removal was unintended, check presence and reinstall.
HWC1001
Message
The <
name
> is absent.
LCD Message
The <
name
> is absent. Check hardware.
Details
The absent device may be necessary for proper operation.
System functionality may be degraded.
Action
Reinstall or reconnect the hardware.
HWC1002
Message
The <
name
> is disabled.
Action
If device disabled unexpectedly, re-enable device.
HWC1005
Message
The storage adapter is absent.
LCD Message
The storage adapter is absent. Check hardware.
Details
The storage adapter may be necessary for proper operation.
System functionality may be degraded.
Action
Install storage adapter.
HWC1006
Message
The storage adapter is disabled.
Action
If adapter disabled unexpectedly, re-enable the storage
adapter.
HWC1009
Message
The backplane is absent.
LCD Message
The backplane is absent. Check hardware.
99