38
About Your System
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
A fatal system error
occurred and caused the
system to reboot.
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 133 for
any faulty components
specified in the SEL.
Warning! No micro
code update loaded
for processor
n
A microcode update
failed.
Update the BIOS firmware.
If the problem persists, see
"Getting Help" on page 175.
Warning! Detected
missing RAID
hardware for the
embedded RAID
subsystem.
RAID key or RAID DIMM
missing when system is in
RAID mode.
Information only.
Warning! Detected
mode change from
SCSI to RAID on
channel x of the
embedded RAID
subsystem.
The embedded RAID
subsystem configuration
has changed in System
Setup.
See "Using the System Setup
Program" on page 42.
Warning! Detected
mode change from
RAID to SCSI on
channel
n
of the
embedded RAID
subsystem.
The embedded RAID
subsystem configuration
has changed in System
Setup.
See "Using the System Setup
Program" on page 42.
Warning! Embedded
RAID firmware is
not present.
The embedded RAID
firmware does not
respond.
See "Using the System Setup
Program" on page 42.
Warning! Embedded
RAID error!
The embedded RAID
firmware responds with an
error.
See "Using the System Setup
Program" on page 42.
Table 1-6.
System Messages
(continued)
Message
Causes
Corrective Actions