Alert Message
Description/Meaning or Action
File server failed multiple times. Entering Maintenance
mode.
Contact Dell Support for possible support assistance or
intervention.
Insufficient disk space exists.
The filesystem is now read-only.
Unable to detect filesystem type on the Data volume.
Contact Dell Support for possible support assistance or
intervention.
Unable to detect filesystem type on the Namespace
volume.
Contact Dell Support for possible support assistance or
intervention.
Filesystem scan discovered inconsistencies.
Please check the filesystem report, and perform the
suggested action. Contact Dell Support for possible
assistance or intervention.
Replication peer network disconnected.
Check access to remote site.
NVRAM does not match the data volume.
If this is a newly replaced NVRAM, use the maintenance --
hardware --reinit_nvram command to reinitialize the
NVRAM.
For more information, see the
Dell DR Series System
Command Line Reference Guide
.
Storage usage is approaching the system capacity.
Clean up the filesystem. If issue persists, contact Dell
Support for possible assistance or intervention.
Replication resync cannot proceed.
Namespace limit has reached its maximum.
Out of space on replication target.
Clean up the filesystem. If issue persists, contact Dell
Support for possible assistance or intervention.
The filesystem has reached the maximum allowable limit
for files and directories. Creating new files and
directories will be denied.
Clean up the filesystem. If issue persists, contact Dell
Support for possible assistance or intervention.
System Chassis Alerts
Power Supply <
number
> detected a failure.
•
Reconnect the power cable to the designated
power supply unit if it is disconnected.
•
Ensure that there is input AC power at the power
cable.
•
Use a different power cord.
If this does not resolve the issue, replace the designated
power supply.
Power Supply <
number
> is missing or has been removed.
•
The power supply might not be making a proper
connection.
•
Try reseating the power supply in the power
supply slot.
•
Reconnect the power cable to the designated
power supply unit if it is disconnected.
•
Ensure that there is input AC at the power cable.
•
Use a different power cord.