Script Commands
167
freeCapacityArea
Index number of the free space in an
existing disk group to use to create the
new virtual disk. Free capacity is defined
as the free capacity between existing
virtual disks in a disk group. For example, a
disk group might have the following areas:
virtual disk 1, free capacity, virtual disk 2,
free capacity, virtual disk 3, free capacity.
To use the free capacity following virtual
disk 2, specify:
freeCapacityArea=2
Use the
show diskGroup
command to
determine if the free capacity area exists.
capacity
Size of the virtual disk that you are adding
to the storage array. Size is defined in
units of bytes, KB, MB, GB, or TB.
NOTE:
Add a space between the last digit
and the size (bytes, KB, MB, or GB) for
values greater than 9. If you do not specify
a capacity, all the available physical disk
capacity in the disk group is used. If you do
not specify the capacity unit, bytes is used
as the default unit.
owner
RAID controller module that owns the
virtual disk. Valid RAID controller module
identifiers are
0
or
1
, where, 0 is the RAID
controller module on the left and 1 is the
RAID controller module on the right
when viewed from the rear of the
enclosure. If you do not specify an owner,
the RAID controller module firmware
determines the owner.
NOTE:
The
owner
parameter defines
which RAID controller module owns the
virtual disk. The preferred RAID controller
module ownership of a virtual disk is the
RAID controller module that currently owns
the disk group.
Parameter
Description
book.book Page 167 Wednesday, June 8, 2011 12:20 PM
Summary of Contents for PowerVault MD3600f Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 44: ...44 About the Script Commands ...
Page 114: ...114 Using the Remote Replication Premium Feature ...
Page 311: ...Script Commands 311 ...
Page 312: ...312 Script Commands ...
Page 318: ...318 Sample Script Files ...
Page 328: ...Index 328 ...