Script Commands
215
Reset Storage Array Battery Install Date
This command resets the age of the batteries in a storage array to zero days.
You can reset the batteries for an entire storage array or just the battery for a
specific RAID controller module or in a specific battery pack.
Syntax
reset storageArray batteryInstallDate controller=
(0 | 1)
Parameters
NOTE:
If you do not specify a RAID controller module, the age is reset for the
storage array battery or both RAID controller module batteries. If you specify a
RAID controller module, then the age for only that RAID controller module battery is
reset.
Parameter
Description
controller
Specifies the RAID controller module that contains the battery
for which to reset the age. Valid RAID controller module
identifiers are
0
or
1
, where,
0
is the RAID controller module on
the left, and
1
is the RAID controller module on the right when
viewed from the rear of the enclosure. Use the
controller
parameter only for RAID controller modules with batteries.
book.book Page 215 Wednesday, June 8, 2011 12:20 PM