276
Script Commands
Show Physical Disk Download Progress
This command returns the status of firmware downloads for the physical disks
targeted by the
download physicalDisk firmware
or
download storageArray
physicalDiskFirmware
commands.
Syntax
show allPhysicalDisks downloadProgress
Parameters
None.
NOTE:
When all firmware downloads have successfully completed, this command
returns a
Successful
status. If any firmware downloads fail, this command shows
the firmware download status of each targeted physical disk. This command returns
the status values shown in the following table.
Show RAID Controller Module
For each RAID controller module in a storage array, this command returns the
following information:
• Status (Online, Offline)
• Current firmware and NVSRAM configuration
• Pending firmware and NVSRAM configuration configurations (if any)
• Board ID
• Product ID
• Product revision
• Serial number
• Date of manufacture
Status
Definition
Successful
Downloads completed without errors.
Not Attempted
Downloads did not start.
Partial Download
Downloads are in progress.
Failed
Downloads completed with errors.
book.book Page 276 Wednesday, June 8, 2011 12:20 PM
Summary of Contents for PowerVault MD3600f Series
Page 1: ...Dell PowerVault Modular Disk Storage Arrays CLI Guide ...
Page 44: ...44 About the Script Commands ...
Page 114: ...114 Using the Remote Replication Premium Feature ...
Page 311: ...Script Commands 311 ...
Page 312: ...312 Script Commands ...
Page 318: ...318 Sample Script Files ...
Page 328: ...Index 328 ...