• Provide a suitable power source with electrical overload protection. All Storage Center components 

must be grounded before applying power. Make sure that there is a safe electrical earth connection to 

power supply cords. Check the grounding before applying power.

• The plugs on the power supply cords are used as the main disconnect device. Make sure that the 

socket outlets are located near the equipment and are easily accessible.

• Know the locations of the equipment power switches and the room's emergency power-off switch, 

disconnection switch, or electrical outlet.

• Do not work alone when working with high-voltage components.
• Unplug the chassis before you move it or if you think it has become damaged in any way. When 

powered by multiple AC sources, disconnect all supply power for complete isolation.

Electrostatic Discharge Precautions

Always follow electrostatic discharge (ESD) precautions to avoid injury and damage to Storage Center 

equipment.

Electrostatic discharge (ESD) is generated by two objects with different electrical charges coming into 
contact with each other. The resulting electrical discharge can damage electronic components and 
printed circuit boards. Follow these guidelines to protect your equipment from ESD:

• Dell recommends that you always use a static mat and static strap while working on the storage 

controller.

• Use a suitable ESD wrist or ankle strap.

General Safety Precautions

Always follow general safety precautions to avoid injury and damage to Storage Center equipment.

• Keep the area around the storage system chassis clean and free of clutter.
• Place any system components that have been removed away from the storage system chassis or on a 

table so that they are not in the way of foot traffic.

• While working on the storage system chassis, do not wear loose clothing such as neckties and 

unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a 

cooling fan.

• Remove any jewelry or metal objects from your body because they are excellent metal conductors 

that can create short circuits and harm you if they come into contact with printed circuit boards or 

areas where power is present.

• Do not lift a storage controller by the handles of the power supply units (PSUs). They are not designed 

to hold the weight of the entire chassis, and the chassis cover may become bent.

• Before moving a storage controller, remove the PSUs to minimize weight.

Replacing the Front Bezel

1.

Use the system key to unlock the keylock at the left end of the bezel.

2.

Lift the release latch next to the keylock.

3.

Rotate the left end of the bezel away from the front panel.

4.

Unhook the right end of the bezel and pull the bezel away from the storage controller.

12

Replacing SC9000 Storage System Components

Summary of Contents for SC9000

Page 1: ...Dell Storage Center SC9000 Storage System Owner s Manual Regulatory Model E09J E10J Regulatory Type E09J001 E10J001 ...

Page 2: ... problem WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2016 Dell Inc All rights reserved This product is protected by U S and international copyright and intellectual property laws Dell and the Dell logo are trademarks of Dell Inc in the United States and or other jurisdictions All other marks and names mentioned herein may be trademarks of their re...

Page 3: ...Replacing SC9000 Storage System Components 11 Safety Precautions 11 Installation Safety Precautions 11 Electrical Safety Precautions 11 Electrostatic Discharge Precautions 12 General Safety Precautions 12 Replacing the Front Bezel 12 Pre Replacement Procedures 13 Send Diagnostic Data Using Dell SupportAssist 13 Shut Down a Storage Controller 13 Replacing Rack Rails 14 Post Replacement Procedures 1...

Page 4: ... intended for use by Dell end users Contacting Dell Dell provides several online and telephone based support and service options Availability varies by country and product and some services may not be available in your area To contact Dell for sales technical support or customer service issues go to www dell com support For customized support enter your system Service Tag on the support page and c...

Page 5: ... in three full height slots and three low profile slots The Storage Center Operating System is installed on an embedded SSD within each storage controller The IO cards in the storage controller are designated as front end ports or back end ports Front end ports Hosts servers or Network Attached Storage NAS appliances access storage by connecting to the storage controller iSCSI Fibre Channel or FCo...

Page 6: ...and back panels can be used to locate a particular system within a rack When one of these buttons is pressed the front LCD panel and the back system status indicator flash until one of the buttons is pressed again Press to toggle the system ID on and off If the system stops responding during POST press and hold the system ID button for more than five seconds to enter BIOS progress mode To reset th...

Page 7: ...r is turned on or off 8 Filler plate Covers empty bay 9 vFlash media card slot Not used for the SC9000 10 iDRAC USB Connects USB devices to the system or provides access to the iDRAC Direct features The USB management port is USB 2 0 compliant 11 Management USB Connects USB devices to the system The USB management port is USB 2 0 compliant 12 Storage Center OS drive An internal SSD drive that hold...

Page 8: ...t to right 5 Serial connector Connects a serial device to the system 6 Video connector Connects a VGA display to the system 7 USB connector 2 Connects USB devices to the system The ports are USB 3 0 compliant 8 Full height IO card slots 3 Ports are numbered from right to left 9 Ethernet connectors Connects the storage controller to the Ethernet switch and to other storage controllers in the rack T...

Page 9: ...s in standby mode and can be turned on by pressing either the Select Left or Right button on the LCD panel The LCD backlight remains off if LCD messaging is turned off through the iDRAC utility the LCD panel or other tools Figure 3 LCD Panel Features Item Button Description 1 Left Moves the cursor back in one step increments 2 Select Selects the menu item highlighted by the cursor 3 Right Moves th...

Page 10: ...scription Set home Select the default information to be displayed on the LCD Home screen See View menu for a description of the options that can be set as the default on the Home screen View Menu The View menu displays iDRAC asset power and temperature information NOTE When you select an option in the View menu you must confirm the option before proceeding to the next action Option Description iDR...

Page 11: ...orage system is always fully grounded to prevent damage from electrostatic discharge When handling the storage system hardware use an electrostatic wrist guard not included or a similar form of protection The chassis must be mounted in a rack The following safety requirements must be considered when the chassis is being mounted The rack construction must be capable of supporting the total weight o...

Page 12: ...ic mat and static strap while working on the storage controller Use a suitable ESD wrist or ankle strap General Safety Precautions Always follow general safety precautions to avoid injury and damage to Storage Center equipment Keep the area around the storage system chassis clean and free of clutter Place any system components that have been removed away from the storage system chassis or on a tab...

Page 13: ...ow The Send Support Assist Data Now dialog box appears 3 Select Storage Center Configuration and Detailed Logs 4 Click OK Shut Down a Storage Controller Use Dell Storage Client to shut down a storage controller About this task Shutting down one storage controller causes the Storage Center to fail over to the other storage controller which continues to process I O Steps 1 Use the Dell Storage Clien...

Page 14: ... storage controller Next steps Use SupportAssist to send diagnostic data to Dell Technical Support Services Post Replacement Procedures Start up the storage controller if it was previously shut down and use SupportAssist to send diagnostic data to Dell Technical Support Services Start Up the Storage Controller If the storage controller was previously shut down perform this procedure to start it up...

Page 15: ...tion 3 Expansion slots using riser card Riser 1 Slot 1 One half height low profile x8 link Slot 2 One half height low profile x8 link Slot 3 One half height low profile x8 link Riser 2 Slot 4 One full height full length x16 link Slot 5 One full height full length x8 link Riser 3 Slot 6 One full height full length x8 link Slot 7 One full height full length x8 link Memory Architecture 2133 MT s DDR4...

Page 16: ...ximum configuration weight 44 lb Environmental For additional information about environmental measurements for specific storage system configurations see dell com environmental_datasheets Temperature Storage 40 to 65 C 40 to 149 F Continuous operation for altitude less than 950 m or 3117 ft 10 C to 35 C with no direct sunlight on the equipment Fresh air For information about fresh air see Expanded...

Page 17: ...OTE This section defines the limits to help avoid IT equipment damage and or failure from particulates and gaseous contamination If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage or failures to your equipment it maybe necessary for you to re mediate the environmental conditions that are causing the damage or...

Page 18: ...10 C to 35 C the system can operate continuously down to 5 C or as high as 40 C For temperatures between 35 C and 40 C de rate maximum allowable temperature by 1 C per 175m above 950 m 1 F per 319 ft 1 of annual operating hours 5 C to 45 C at 5 to 90 RH with 29 C dew point NOTE Outside the standard operating temperature 10 C to 35 C the system can operate down to 5 C or up to 45 C for a maximum of...