Troubleshooting SC200/220
Components
This section contains basic troubleshooting steps for components inside the SC200 and
SC220 enclosures.
Contents
Troubleshooting Power Supply/Cooling Fan Modules . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting Enclosure Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting Power Supply/Cooling Fan Modules
Use these steps to troubleshoot power supply/cooling fan modules.
1
Check the status of the power supply/cooling fan module using the Storage Center
System Manager.
2
Determine the status of the power supply/cooling fan module LEDs.
•
If the power supply/cooling fan module fault indicator is lit, the power supply/cooling
fan has failed.
•
If the AC power LED is not lit, check the power cord and power source into which the
power supply is plugged:
•
Connect another device to the power source and check whether the device
works.
•
Connect the power cord to a different power source.
•
Replace the power cord.
•
If the DC power LED is not lit, verify that the power switch is turned on.
3
Reseat the power supply/cooling fan module by removing and reinstalling it.
Note:
Allow several seconds for the enclosure to recognize the power supply/
cooling fan module and determine its status.