30
SAS 5/iR BIOS
View Virtual Disk
The
View Virtual Disk
screen allows you to view the current virtual disk configuration.
Press <Alt+N> to view the next virtual disk. See the table above to view descriptions of each
virtual disk property.
Manage Virtual Disk
The
Manage Virtual Disk
screen is used to manage the current virtual disk. If you select
Synchronize
Mirror
,
Activate Mirror
, or
Delete Virtual Disk
, you are prompted to confirm the choice by pressing
Y
for yes or
N
for no.
RAID Disk
Specifies whether the disk is part of a RAID virtual disk (Yes or No). This field is grayed
out under the following conditions:
• The disk does not meet the minimum requirements for use in a RAID virtual disk.
• The disk is not large enough to mirror existing data on the primary physical disk.
• The disk is a part of another virtual disk.
Pred Fail
Indicates whether device SMART is predicting device failure
Drive Status
The physical disk drive status
•
Ok
: Disk is online and fully functional
•
Missing
: Disk is not detected
•
Failed
: Disk is not accessible or has reported a failure
•
Initing
: Disk is initializing
•
Offline
: Disk is offline for some other reason
•
Inactive
: Disk has been set inactive
•
Not Syncd
: Data on disk is not synchronized with the rest of the virtual disk
•
Primary
: Disk is the primary disk for a 2-disk mirror and is OK
•
Secondary
: Disk is the secondary disk for a 2-disk mirror and is OK
•
Wrg Type
: Device is not compatible for use as part of the RAID virtual disk
•
Too Small
: Disk is too small to mirror existing data
•
Max Dsks
: Maximum # of disks allowed for this type of virtual disk reached
•
Wrg Intfc
: Device interface (SAS/SATA) differs from existing IR disks
Size (MB)
The coerced size of the physical disk in MB (1 MB = (1024 x 1024) = 1,048,576 bytes).
NOTE:
Disk coercion is used to ensure the disks are the same size. In virtual disks consisting
of different sized physical disks, excess space on larger physical disks is unusable.
Table 5-2.
Virtual Disk Field Descriptions
(continued)
Field
Description
YD912bk1.book Page 30 Monday, April 2, 2007 4:39 PM
Summary of Contents for UCS-51
Page 2: ...YD912bk1 book Page 2 Monday April 2 2007 4 39 PM ...
Page 14: ...12 Overview YD912bk1 book Page 12 Monday April 2 2007 4 39 PM ...
Page 20: ...18 Hardware Installation YD912bk1 book Page 18 Monday April 2 2007 4 39 PM ...
Page 44: ...42 Updating the Firmware YD912bk1 book Page 42 Monday April 2 2007 4 39 PM ...
Page 52: ...50 Regulatory Notices YD912bk1 book Page 50 Monday April 2 2007 4 39 PM ...
Page 53: ...Regulatory Notice 51 YD912bk1 book Page 51 Monday April 2 2007 4 39 PM ...
Page 54: ...52 Regulatory Notices YD912bk1 book Page 52 Monday April 2 2007 4 39 PM ...
Page 55: ...Regulatory Notice 53 YD912bk1 book Page 53 Monday April 2 2007 4 39 PM ...
Page 56: ...54 Regulatory Notices YD912bk1 book Page 54 Monday April 2 2007 4 39 PM ...
Page 58: ...56 Regulatory Notices YD912bk1 book Page 56 Monday April 2 2007 4 39 PM ...
Page 59: ...Regulatory Notice 57 YD912bk1 book Page 57 Monday April 2 2007 4 39 PM ...
Page 60: ...58 Regulatory Notices YD912bk1 book Page 58 Monday April 2 2007 4 39 PM ...
Page 66: ...64 Glossary YD912bk1 book Page 64 Monday April 2 2007 4 39 PM ...