38
Troubleshooting
BIOS Error Messages
Table 6-4.
BIOS Error Messages
Message
Meaning
Press <Ctrl+C> to Enable BIOS
When the BIOS is disabled, you are given the option to
enable it by entering the configuration utility. You can
change the setting to
Enabled
in the configuration utility.
Adapter at Baseport xxxx is not
responding where xxxx is the
baseport of the controller
If the controller does not respond for any reason but is
detected by the BIOS, it displays this warning and continues.
Shut down the system and try to reseat the controller. If this
message appears again, Contact Dell.
Following SAS targets are not
responding...
When the BIOS determines that previously configured
physical disks are not connected to the controller, the BIOS
displays this warning and continues to boot. The system
continues to boot. See "Physical Disk Related Issues" on
page 36 for troubleshooting tips.
Adapter configuration may have
changed, reconfiguration is
recommended!
Press CTRL-C to run Dell SAS 5
Configuration Utility…
Start the Configuration Utility and confirm the configuration
of the SAS 5/iR controller.
Initializing...
Displays while the BIOS is waiting to initialize.
SAS discovery error
Indicates that there was a discovery error reported by the
firmware and may be accompanied by more such messages.
Enter the Configuration Utility to investigate.
Integrated RAID exception detected:
The BIOS detected an exception with one or more RAID
virtual disk. For additional troubleshooting information, see
the error message "
Volume (xx:yy:zzz) is
currently in state “STATE”
.
Volume (xx:yy:zzz) is currently in
state “STATE”
Lists the current state of the specified virtual disk when it is
not optimal. The state may include:
• INACTIVE: The virtual disk is inactive, possibly foreign, or
could be in any one of the states mentioned below.
• DEGRADED: The virtual disk is in a degraded state and has
lost redundancy.
• RESYNCING: The virtual disk is degraded and currently
rebuilding.
• FAILED: The virtual disk has an error and is in a failed state.
• MISSING: The virtual disk is no longer present though a
record of it remains.
YD912bk1.book Page 38 Monday, April 2, 2007 4:39 PM
Summary of Contents for UCS-51
Page 2: ...YD912bk1 book Page 2 Monday April 2 2007 4 39 PM ...
Page 14: ...12 Overview YD912bk1 book Page 12 Monday April 2 2007 4 39 PM ...
Page 20: ...18 Hardware Installation YD912bk1 book Page 18 Monday April 2 2007 4 39 PM ...
Page 44: ...42 Updating the Firmware YD912bk1 book Page 42 Monday April 2 2007 4 39 PM ...
Page 52: ...50 Regulatory Notices YD912bk1 book Page 50 Monday April 2 2007 4 39 PM ...
Page 53: ...Regulatory Notice 51 YD912bk1 book Page 51 Monday April 2 2007 4 39 PM ...
Page 54: ...52 Regulatory Notices YD912bk1 book Page 52 Monday April 2 2007 4 39 PM ...
Page 55: ...Regulatory Notice 53 YD912bk1 book Page 53 Monday April 2 2007 4 39 PM ...
Page 56: ...54 Regulatory Notices YD912bk1 book Page 54 Monday April 2 2007 4 39 PM ...
Page 58: ...56 Regulatory Notices YD912bk1 book Page 56 Monday April 2 2007 4 39 PM ...
Page 59: ...Regulatory Notice 57 YD912bk1 book Page 57 Monday April 2 2007 4 39 PM ...
Page 60: ...58 Regulatory Notices YD912bk1 book Page 58 Monday April 2 2007 4 39 PM ...
Page 66: ...64 Glossary YD912bk1 book Page 64 Monday April 2 2007 4 39 PM ...