background image

www.dellonda.co.uk 11

•  Lock the control panel when you are away to 

prevent other people changing your settings.

•  Press the massage button to activate the 

bubble massage system, the green indicator 

light turns on. It can be turned off by pressing 

it again.

•  Note: The massage system will stop 

automatically after 30 minutes of operation. 

Re-activate the massage function by pressing 

the massage button again.

• 

When the filter button is on, pressing the 

massage button will turn filter mode into 

massage mode: filter indicator light will turn 

off and massage indicator light will turn on. If 

you press the massage button again, the 

massage mode will be changed back to filter 

mode.

• 

Press the filter button to activate the water 

filtration. The green indicator light will turn on 

when the filtration system is activated.

• 

Note: If massage function is on, the filtration 

can’t be activated.

•  Press the heater button to activate the water 

heating and filtering system at the same time. 

The green indicator light of the filter and red 

indicator light of the heater will turn on at the 

same time.

Control Panel

Functions

•  Once powered-up, the 

LED

 displays the current 

water temperature automatically.

•  The temperature units selector changes the 

temperature units from Celsius to Fahrenheit.

•  Press the temperature adjustment buttons, 

then the screen will flash. When it 

is flashing, you can set the desired 

temperature. The value will 

increase or decrease 1 degree at a 

time. The temperature could be 

set between 30°C to 40°C (86°F to 

104°F).

•  To lock or unlock the control 

panel, press the Lock button and 

hold 3 seconds.

1

Filtration

2

Heat Button

3

Massage Button

4

Lock Button

5

LED Display

6

Temperature Units Indicator

7

Temperature Decrease Button

8

Temperature Unit Selection

9

Temperature Increase Button

•  The pump does not stop heating until the 

current water temperature reaches the set 

temperature; and the heating system will 

restart after the current water temperature 

drops 2°C below the set temperature 

automatically.

•  Maximum heating temperature: 40°C (104°F).

•  Important :

• 

After 150 cumulative hours of filtration 

operations, an audible alarm will sound and 

the 

LCD

 display will show the characters 

CHG

followed by 

FIL

, to remind you to change 

or clean the filter. You can hold the filtering 

button for 5 seconds to turn off the buzzing. 

The filtering system will turn off, you can press 

the button to activate the filtering system 

again.

•  Note : When the heating system is started the 

filtration system will start working as well.

•  After turning off the heating system, the 

filtration system will still work.

• 

If the massage function is active, the filtration 

and heating functions can not be activated.

Spa Cover and Security

•  After each use, the control panel must be 

locked and the spa must be covered with 

its top cover and it must be attached to the 

ground sheet with each safety buckle .

•  Always keep the spa cover on to minimize 

heat loss during heating of the spa and 

between uses (but not while it is being used). 

Ensure the cover is fitted tightly, as per these 

instructions to maximize insulation. It is 

recommended that the cover, when not in 

use, should be kept off the ground to retain its 

cleanliness (particularly the surface in close 

proximity to the water surface). The cover 

should be stored in an appropriate location, 

where it cannot be damaged, or cause 

damage.

•  Check the set water temperature and consider 

lowering it for the times when the spa will 

typically not be in use.

Summary of Contents for DL16

Page 1: ...del No DL16 DL17 DL23 DL24 Thank you for purchasing a Dellonda product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years...

Page 2: ...correctly and with care for the purpose for which it is intended Failure to do so may cause damage and or personal injury and will invalidate the warranty Keep these instructions safe for future use C...

Page 3: ...del DL17 Water Capacity 1200L 264 gal Inner Dimensions 160 x 70cm Outer Dimensions 204 x 70cm Capacity 4 6 People Bubble Jet Holes 140 Massage Bubble Power 650W Heating Rate 1 5 2 5 C hr Maximum Water...

Page 4: ...helpful aids but they are not substitutes for continuous and competent adult supervision Safety equipment 1 It is recommended to keep rescue equipment e g a lifebuoy by the spa 2 Keep a working phone...

Page 5: ...e unit to electric supply provide a properly located outlet The spa electrical appliance is supplied through a residual current device RCD having a rated residual operating current not exceeding 10mA...

Page 6: ...of impending hazard foetal damage in pregnant women physical inability to exit the spa and unconsciousness resulting in the danger of drowning Obese persons or persons with a history of heart disease...

Page 7: ...a competent electrician It is recommended that this heater is wired directly to a fused isolator switch If however a plug is fitted the following applies Fit a new plug according to the following inst...

Page 8: ...eas and relaxing areas shall be considered in the cleaning process as well No cleaning agent should flow into the spa or spa water cycle The dirt and cleaning agents shall be rinsed carefully to a dra...

Page 9: ...spa 5 Connect the pump unit then press the massage button to inflate the spa The air flow valve prevents your spa from over inflating 6 Inflate the inflatable spa for about 10 minutes Ensure that the...

Page 10: ...it fills evenly Continue filling the spa to the level indicated Control Panel Functions Once powered up the LED displays the current water temperature automatically The temperature units selector cha...

Page 11: ...rature automatically Maximum heating temperature 40 C 104 F Important After 150 cumulative hours of filtration operations an audible alarm will sound and the LCD display will show the characters CHG f...

Page 12: ...structions Damage resulting from improper use of treatment products is not covered by warranty overdose shock treatment Water balance The water balance pH must be maintain between 7 and 7 4 Water Sani...

Page 13: ...can be cleaned with soap and water Storage NOTE Whenever the spa is emptied the filter should be cleaned and dried where applicable 1 Press the massage button to blow out the water inside the jet hol...

Page 14: ...ctrician to reset the thermal cutout described in next paragraph If this does not solve the problem refer to the box below E6 Not heating and filtering properly alarm sounding Water pressure is not en...

Page 15: ...ait 30 minutes and press the massage button to reactivate Malfunction of the pump unit Call for service if it does not reset Water filtration does not work Filter Cartridge is dirty Clean or Replace t...

Page 16: ...nger required or has reached the end of it s useful life please dispose of it in an environmentally friendly way Drain any fluids if applicable into approved containers in accordance with local waste...