background image

14 www.dellonda.co.uk

Code Situation

Problem

Possible Causes

Suggested Solutions

E1

Not heating/ 

Not heating 

properly.

Faulty 

temperature 

control sensor.

Temperature control 

sensor short circuit 

or open circuit.

Contact service centre 01284  

757575

E3

Not heating 

properly.

High water 

temperature 

indicator.

1. The filled water is 

over 45°C (113°F)

2.The filter cartridge 

was put on the wrong 

suction fitting (higher 

suction fitting).

1.Cut off the power, 

make sure the pool 

water is between 

2°C~40°C(36°F~104°F).

If this does not solve the 

problem, refer to the box 

below.

E4

All functions 

do not 

work, alarm 

sounding.

Low water 

temperature 

indicator.

The pool water is 

lower than 2°C

(36°F).

·Turn off the power, 

make sure the spa water 

is between 2°C~40°C 

(36°F~104°F)

· If this does not solve the 

problem, refer 

to the box below.

E5

All functions 

do not 

work, alarm 

sounding.

High water 

temperature 

indicator.

The filled water is 

over 50°C (122°F).

·Turn off the power, contact a 

qualified electrician to reset 

the thermal cutout described 

in next paragraph.

· If this does not solve the 

problem, refer to the box 

below.

E6

Not heating 

and filtering 

properly, alarm 

sounding..

Water pressure 

is not enough to 

activate heating.

·Inlet or outlet 

on inner wall are 

blocked.

·Filter cartridge is too 

dirty.

·Pool water does 

not reach minimum 

water level.

·Air trapped in pump.

·Pump is faulty.

·Clean inlet and outlet.

·Clean or replace filter 

cartridge.

·Add water to reach water 

level.

·Release air from pump. 

· If this does not solve the 

problem, refer to trouble 

shooting on page 15.

Error Codes Table

Error Codes

•  E3, E4, E5, E6 error codes.

•  If error code is displayed on the control Box, please carry out the following instructions 

•  1 - Check that the water line is between the high and low limits.

•  2 - Unscrew and clean the 2 nozzles (Entry and exit of water) inside the spa and remove wastes if 

necessary (leaves, hairs, fur, skin etc.) other foreign matter.

•  Disconnect the power supply for 5 minutes and re-connect it. If the error code is still displayed on 

the control box please contact the Service Centre on: 01284 757575.

•  If the screen displays an error code “Ex”, please refer to the table page 15.

Summary of Contents for DL88

Page 1: ...del No DL88 DL89 DL90 DL91 Thank you for purchasing a Dellonda product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years...

Page 2: ...correctly and with care for the purpose for which it is intended Failure to do so may cause damage and or personal injury and will invalidate the warranty Keep these instructions safe for future use C...

Page 3: ...del DL89 Water Capacity 1200L 264 gal Inner Dimensions 160 x 70cm Outer Dimensions 204 x 70cm Capacity 4 6 People Bubble Jet Holes 140 Massage Bubble Power 650W Heating Rate 1 5 2 5 C hr Maximum Water...

Page 4: ...helpful aids but they are not substitutes for continuous and competent adult supervision Safety equipment 1 It is recommended to keep rescue equipment e g a lifebuoy by the spa 2 Keep a working phone...

Page 5: ...e unit to electric supply provide a properly located outlet The spa electrical appliance is supplied through a residual current device RCD having a rated residual operating current not exceeding 10mA...

Page 6: ...g hazard foetal damage in pregnant women physical inability to exit the spa and unconsciousness resulting in the danger of drowning Obese persons or persons with a history of heart disease low or high...

Page 7: ...recommended that this heater is wired directly to a fused isolator switch If however a plug is fitted the following applies Fit a new plug according to the following instructions UK only A Connect th...

Page 8: ...areas shall be considered in the cleaning process as well No cleaning agent should flow into the spa or spa water cycle The dirt and cleaning agents shall be rinsed carefully to a drain in the spa ens...

Page 9: ...spa 5 Connect the pump unit then press the massage button to inflate the spa The air flow valve prevents your spa from over inflating 6 Inflate the inflatable spa for about 10 minutes Ensure that the...

Page 10: ...it fills evenly Continue filling the spa to the level indicated Control Panel Functions Once powered up the LED displays the current water temperature automatically The temperature units selector cha...

Page 11: ...rature automatically Maximum heating temperature 40 C 104 F Important After 150 cumulative hours of filtration operations an audible alarm will sound and the LCD display will show the characters CHG f...

Page 12: ...structions Damage resulting from improper use of treatment products is not covered by warranty overdose shock treatment Water balance The water balance pH must be maintain between 7 and 7 4 Water Sani...

Page 13: ...can be cleaned with soap and water Storage NOTE Whenever the spa is emptied the filter should be cleaned and dried where applicable 1 Press the massage button to blow out the water inside the jet hol...

Page 14: ...ctrician to reset the thermal cutout described in next paragraph If this does not solve the problem refer to the box below E6 Not heating and filtering properly alarm sounding Water pressure is not en...

Page 15: ...ait 30 minutes and press the massage button to reactivate Malfunction of the pump unit Call for service if it does not reset Water filtration does not work Filter Cartridge is dirty Clean or Replace t...

Page 16: ...nger required or has reached the end of it s useful life please dispose of it in an environmentally friendly way Drain any fluids if applicable into approved containers in accordance with local waste...