18
SELF-DIAGNOSIS
The appliance has a self diagnosis system to identify a number of warning/malfunctions.
Error messages are displayed on the appliance display.
IF ... IS DISPLAYED,
IF ... IS DISPLAYED,
IF ... IS DISPLAYED,
IF ... IS DISPLAYED,
“Low Temperature”
(Frost prevention)
“Probe Failure”
(Probe damaged)
“High Level”
(Internal tray full)
“Communication Failure”
(Internal communication issue)
..WHAT SHOULD I DO?
..WHAT SHOULD I DO?
..WHAT SHOULD I DO?
..WHAT SHOULD I DO?
The appliance is fitted with a
frost protection device to avoid
excessive formation of ice. The
appliance starts up again auto-
matically when the defrosting
process is completed.
If this is displayed, contact your
local authorized service center
Empty the internal safety tank
following the instructions in the
section “End of
season operations”
If this is displayed, contact your
local authorized service center.
timer button only one time, the remaining hours to shut down
will be displayed.
How to program delayed start up
• Plug in the appliance and set to standby.
• Touch the
C1
C2
C4
C11
C13
C12
C9
C7
C5
C6
C3
C16
C14
C10
C15
C17
C8
timer button (D5): the timer symbol (C7) and
hours (C6) light up.
• Touch the (D4) and (D7)
buttons until the desired
numbers of hours to start up appears. Start up can be pro-
grammed at any time within the 24 hours that follow.
When the set time is elapsed, the appliance will start to operate
in the same operating mode that was previously set.
To cancel the timer program, touch the timer button (D5) twice.
The timer symbol (C7) will go off.
Please note:
Once the timer has been activated, by touching the
timer key only one time, the remaining hours to the start up will
be displayed.
USAGE TIPS
• The CST remote control has humidity/temperature sensors
onboard. It is suggested not to completely cover it with
hands or clothes; it is as well suggested not to place in ob-
structed air flow zones. In addition to that it is preferable
to keep the device far for direct sunlight exposure or heat
sources in order to avoid miss sensor readings.
• The CST remote control is equipped with touch sensitive
buttons. It is suggested to use it with clean hands and
without dust or liquids/humidity over it.
• The CST remote control is expected to run for about 6
months with the same battery pack. This assumption is
based on the use of 2300 mAh LR6 “AA” batteries
TIPS FOR CORRECT USE
To ensure optimal results from your air conditioner, follow these
recommendations:
• close the windows and doors in the room to be air condi-
tioned. When installing the air conditioner semi-perma-
nently, you should leave a door slightly open (as little as 1
cm) to guarantee proper ventilation.
• Never use the appliance in very damp rooms (laundries for
example).
• Protect the room from direct exposure to the sun by par-
tially closing curtains and/or blinds to make the appliance
much more economical to run.
• Never use the appliance outdoors.
• Make sure there are no heat sources in the room.
• make sure the air conditioner is standing on a level surface.
do not cover the appliance