6
capacity expanding. For each single module, each terminal can achieve charging and discharging
function.
RESET
RESET Switch: When BMS is in hibernation state, press the button (3~6s) and release it, the
protection plate will be activated, and the LED indicator will light up for 0.5 seconds successively
from "RUN". When BMS is in the active state, press the button (3~6s) and release it, the
protection board will sleep, and the LED indicator will light up for 0.5 seconds from the lowest
battery level light. When BMS is in the active state, press the button (6~10s) and release it, the
protection plate is reset, and all LED lights are on for 1.5 seconds at the same time.
DIP (ADD)
DIP (ADD) Switch: 4 ADD switches, to definite different address code for each battery
module when multiple modules are cascaded, up to 15 addresses.
NOTE
:
The address corresponding to ADD1 in the table is the host, and all other
addresses are the slave
Dry contact
Dry contact: Dry contacts are reserved for external I/O port control signals
2 Safe handling of lithium batteries Guide
2.1 Schematic Diagram of Solution