LEAK TEST
CAUTION BEFORE TESTING
Finding and/or fixing a gas leak is NOT a “DO-IT-YOURSELF” procedure.
NEVER USE THE SIDE BURNER WITHOUT FIRST LEAK TESTING THE GAS
CONNECTIONS.
WARNING: DO NOT USE OPEN FLAME TO CHECK FOR LEAKS. USE OF AN OPEN
FLAME COULD RESULT IN A FIRE, EXPLOSION, BODILY HARM OR DEATH.
DO NOT SMOKE WHILE PERFORMING THE LEAK TEST!
To prevent fire or explosion hazard, DO NOT use or permit sources of ignition in the area
while performing a leak test. Perform leak test outdoors only.
Check to ensure that flexible hoses do not have any cuts and wear that may affect the safety
before each use. Only the factory supplied hose and regulator must be used. Use only
replacement regulator and hose assemblies specified by DELSOL.
LEAK TEST
1)
Prepare a leak testing solution of sudsy water by mixing in a spray bottle with half liquid
soap and half water.
2)
Confirm that all control knobs are in the OFF position.
3)
Turn the main gas valve supply ON.
4)
Apply leak testing solution by spraying on the pipe joints, fittings, and hose.
5)
A gas leak is detected if;
a)
there is a faint gas smell and/or…
b)
…growing bubbles appear on any of the connection points and/or hose, DO NOT attempt
to ignite the side burner and IMMEDIATELY turn off the gas supply valve.
6)
When there is a gas leak, call a qualified service technician. DO NOT use the side burner
until the leak is corrected.