PORTABLE LP CONNECTION
NOTE: USE ONLY A 20-LBS. (5-GALLON CAPACITY) GAS CYLINDER.
WARNING: DO NOT PLACE MORE THAN
ONE
CYLINDER IN THE CABINET
ENCLOSURE AT ANY TIME.
WARNING: DO NOT USE A DENTED OR RUSTED LP CYLINDER.
NEVER USE A CYLINDER WITH A DAMAGED VALVE.
ALWAYS CHECK FOR LEAKS AFTER CHANGING THE LP CYLINDER. (Page 6)
THE HIGH PRESSURE LP REGULATOR (SOLD SEPARATELY) MUST BE USED
WITHOUT ALTERATION.
DELSOL side burners for the use of LP gas
comes equipped with its own regulator, which
MUST NOT
be removed.
1)
To install the gas cylinder, place the cylinder
onto the provided location.
2)
Check to ensure that the tank’s gas valve on
top of the cylinder is closed.
3)
Connect the
3
/
8
” flare end of the hose to the
grill coupling using a ¾” open Wrench. Do
not apply pipe sealant to the
3
/
8
” flare
connection.
4)
Connect the LP regulator to the cylinder and
hand-tighten only. Open the tank valve and
make sure all connections are leak tight using
a soapy water solution and a brush.
(Reference page 6 for leak test procedure).
! WARNING !
DO NOT STORE SPARE LP-GAS CYLINDER UNDER OR NEAR THIS APPLIANCE.
NEVER FILL THE CYLINDER BEYOND 80 PERCENT FULL.
FAILURE TO DO SO, A FIRE CAUSING DEATH OR SERIOUS INJURY MAY
OCCUR.
Typical Freestanding side burner gas hookup
T Adapter
(3/8” Threaded)