- 18 -
- 19 -
Technical Characteristics
7
Siren alarm control unit CS 2000 TYXAL+
- Power supplied by: two 3,6V / 26 Ah lithium batteries
- Class III insulation
- Stand-by consumption: 10 μA max. / Average consumption in transmis
-
sion mode: 25 mA max. / Average consumption in alarm mode: 1,4 A
max.
- 10-year life under normal use.
Low battery voltage: < 2,7 V
-
868,7 -> 869,2 MHz and 868 -> 868,6 MHz
transmission frequencies
- Wireless range from 100 to 300 metres outside, varies depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Wireless alarm equipment
- Environmental class I
- 1.000.000 possible codes
- Maximum number of associated products: 16
- Number of events recorded: 1250
- Sound level at 1 m: 109 dBA +/-2
- Tamper alarm on opening and dislodging
- Indoor use only
- Degree of protection: IP40 - IK06
- Operating temperature: +5°C to +40°C
- Storage temperature: -10°C to +70°C
- Humidity range: 75%
- Dimensions: 176 x 268,5 x 59,5 mm
- Weight (with battery): 900 grams.
- Maximum radio power < 10 mW
- Receiver category II
Wireless touch screen keypad CLT 8000
TYXAL+
- Power supplied by: three LS14500 - 3,6V / 7,8 Ah lithium batteries
- Class III insulation
- Stand-by consumption: <10 μA max.
- Average consumption in transmission mode: 120 mA max.
- 10-year life under normal use.
-
868,7 -> 869,2 MHz and 868 -> 868,6 MHz
MHz transmission frequencies
- Wireless range from 100 to 300 metres outside, varies depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Wireless alarm equipment
- Environmental class 2
- Tamper alarm on opening and dislodging
- Indoor use only
- Degree of protection: IP31 - IK06
- Operating temperature: -10°C to +55°C
- Storage temperature: -10°C to +70°C
- Humidity range: 75%
- Dimensions: 89 x 168 x 28 mm
- Weight (with battery): 270 grams.
- Maximum radio power < 10 mW
- Receiver category II
Wireless door/window magnetic contacts DO
TYXAL+
- Power supplied by: one LS 14500 - 3,6V lithium batteries
- Class III insulation
- Stand-by consumption: 5 μA max.
- Average consumption in transmission mode: 26 mA max.
- 10-year life under normal use.
-
868,7 -> 869,2 MHz and 868 -> 868,6 MHz
MHz transmission frequencies
- Wireless range from 100 to 300 metres outside, varies depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Wireless alarm equipment
- Environmental class 2
- Tamper alarm on opening and dislodging
- Degree of protection: IP30 - IK04
- Operating temperature: -10°C to +55°C
- Storage temperature: -10°C to +70°C
- Humidity range: 75%
- Dimensions:
For fixed part 20,5 x 98,3 x 24,5 mm,
For moving part 12 x 98,3 x 24,5 mm
- Weight (with battery): 66 grams.
- Maximum radio power < 10 mW
- Receiver category II
Wireless dual lens motion detector DMB
TYXAL+
- Power supplied by: one LS 17500 - 3,6V lithium batteries
- Class III insulation
- Stand-by consumption: 5 μA max.
- Average consumption in transmission mode: 26 mA max.
- 10-year life under normal use.
-
868,7 -> 869,2 MHz and 868 -> 868,6 MHz
MHz transmission frequencies
- Wireless range from 100 to 300 metres outside, varies depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Wireless alarm equipment
- Environmental class 2
- Tamper alarm on opening and dislodging
- Degree of protection: IP30 - IK04
- Operating temperature: -10°C to +55°C
- Storage temperature: -10°C to +70°C
- Humidity range: 75%
- Dimensions: 67,8 x 77,3 x 45,3 mm
- Weight (with battery): 90 grams.
- Maximum radio power < 10 mW
- Receiver category II
Wireless remote control for alarms and/or
control systems TL 2000 TYXAL+
- Power supplied by: one CR2430 - 3V lithium batteries
- Class III insulation
- Stand-by consumption: 0,6 μA max. / Average consumption in transmis
-
sion mode: 23 mA max.
- 10-year life under normal use.
-
868,7 -> 869,2 MHz and 868 -> 868,6 MHz
MHz transmission frequencies
- Wireless range from 100 to 300 metres outside, varies depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Wireless alarm equipment
- Environmental class 2
- Degree of protection: IP32
- Operating temperature: -10°C to +55°C
- Storage temperature: -10°C to +70°C
- Humidity range: 75%
- Dimensions: 42 x 65 x 8 mm
- Weight (with battery): 25 grams.
- Maximum radio power < 10 mW
- Receiver category II
TYDOM 1.0 (connected home hub) - Optional
- Adaptor power supply: Input 100-240V~, 50-60 Hz, 0,3 A;
Output 5V=, 1A
- Class II insulation
-
868,7 -> 869,2 MHz
transmission frequency
- Wireless range from 100 to 300 metres outside, varies depending on the
associated equipment (the range can vary depending on the installation
conditions and the electromagnetic environment)
- Degree of protection: IP30 - IK04
- Operating temperature: -10°C to +40°C
- Storage temperature: -20°C to +70°C
- Dimensions: 100 x 100 x 30 mm
- Weight (with battery): 472 grams.
- Maximum radio power < 10 mW
- Receiver category II