ASDA-B2
Chapter 6 Control Modes of Operation
Revision September 2013
6-19
6.3.4 Analog Speed Input Scaling
The analog voltage between
V_REF and GND
determines the motor speed command.
Using with parameter P1-40 (Max. Analog Speed Command) can adjust the speed
control ramp and its range.
5
10
-5
-10
3000rpm
5000rpm
-3000rpm
-5000rpm
Analog Input Voltage (V)
The speed control ramp is
determined by parameter P1-40
Relevant parameters:
P1-40
▲
VCM Max. Analog Speed Command or Limit
Address: 0150H
0151H
Operation
Interface:
Keypad/Software
Communication
Related Section:
Section 6.3.4
Default:
rated speed
Control
Mode:
S, T
Unit: r/min
Range: 0 ~ 10000
Data Size: 16-bit
Display
Format:
Decimal
Settings:
In
Speed mode
, this parameter is used to set the maximum analog speed command
based on the maximum input voltage (10V).
In
Torque mode
, this parameter is used to set the maximum analog speed limit
based on the maximum input voltage (10V).
For example, in speed mode, if P1-40 is set to 3000 and the input voltage is 10V, it
indicates that the speed command is 3000 r/min. If P1-40 is set to 3000, but the input
voltage is changed to 5V, then the speed command is changed to 1500 r/min.
Speed Command / Limit = Input Voltage Value x Setting value of P1-40 / 10
VARITEL INGENIERIA ELECTRONICA S.A.
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.