2.6 EMI Filter Selection
AC Servo Drive - EMI Filter Cross Reference
Item
Power
Servo Drive Model
EMI Filter Model
FootPrint
1PH
3PH
1 100W ASD-B2-0121-B
RF007S21AA
RF022M43AA N
2 200W ASD-B2-0221-B
RF007S21AA
RF022M43AA N
3 400W ASD-B2-0421-B
RF007S21AA
RF022M43AA N
4 750W ASD-B2-0721-B
RF007S21AA
RF022M43AA N
5 1000W ASD-B2-1021-B RF015B21AA
RF075M43BA N
6 1500W ASD-B2-1521-B RF015B21AA
RF075M43BA N
7 2000W ASD-B2-2023-B
-
RF037B43BA N
8 3000W ASD-B2-3023-B
-
RF037B43BA N
Installation
All electrical equipment, including AC servo drives, will generate high-frequency/low-
frequency noise and will interfere with peripheral equipment by radiation or conduction
when in operation. By using an EMI filter with correct installation, much of the interference
can be eliminated. It is recommended to use Delta’s EMI filter to have the best interference
elimination performance.
We assure that it can comply with following rules when AC servo drive and EMI filter are
installed and wired according to user manual:
EN61000-6-4
(2001)
EN61800-3 (2004) PDS of category C2
A2 (2007) Class A Group 1
General Precaution
To ensure the best interference elimination performance when using Delta’s EMI filter,
please follow the guidelines in this user manual to perform wiring and/or installation. In
addition, please also observe the following precautions:
EMI filter and AC servo drive should be installed on the same metal plate.
Please install AC servo drive on same footprint with EMI filter or install EMI filter as
close as possible to the AC servo drive.
All wiring should be as short as possible.
Metal plate should be grounded.
The cover of EMI filter and AC servo drive or grounding should be fixed on the metal