background image

 

 

DELTA ELECTRONICS, INC.

 

8 Jan., 

2008

Rev. 0D

www.deltaww.com

 

  SFP timing parameters for SFP management 

Parameter Symbol 

Min.

Max.

Unit

Unit 

Conditions 

TX_DISABLE Assert 
time 

t_off  

10 

μ

sec

Time from rising edge of TX_DISABLE to 
when the optical output falls below 10% of 
nominal 

TX_DISABLE 
Negate time 

t_on  

msec

Time from falling edge of TX_DISABLE to 
when the modulated optical output rises 
above 90% of nominal 

Time to initialize, 
including reset of 
TX_FAULT 

t_init  

300

msec

From power on or negation of TX_Fault using 
TX Disable. 

TX Fault Assert 
Time 

t_fault 

 

 100

μ

sec Time from fault to TX fault on. 

TX_DISABLE to 
reset 

t_rest 10  

μ

sec

Time TX Disable must be held high to reset 
TX_Fault 

LOS Assert Time 

t_loss_on 

 

100

μ

sec Time from LOS state to Rx LOS assert 

LOS Deassert Time 

t_loss_off 

 

100

μ

sec Time from non-LOS state to Rx LOS deassert

Serial ID Clock Rate  f_serial_clock 

 

100

kHz  

 

Summary of Contents for LCP-155B4JSRx Series

Page 1: ...tion applications that require rates of up to 155Mbit sec It is compliant with the ATM SONET OC 3 SDH STM 1 standards as well as the SFP Multisource Agreement MSA The LCP 155B4JSRx transceivers provide with the LC receptacle that is compatible with the industry standard LC connector The transceiver is also compatible with industry standard RFT connector and cage The post amplifier of the LCP 155B4...

Page 2: ...rential Input Voltage VDT 0 5 2 4 V 1 Transmitter Disable Input High VDISH 2 VCC 0 3 V Transmitter Disable Input Low VDISL 0 0 8 V Transmitter Fault Pull up Resistor RTX_FAULT 4 7 10 kΩ 2 Transmitter Fault Output High VTXFH 2 VCC 0 3 V Transmitter Fault Output Low VTXFL 0 0 8 V Receiver Receiver Differential Output Voltage VDR 0 35 1 2 V 3 Receiver LOS Load RRXLOS 4 7 10 kΩ 2 LOS Output Voltage Hi...

Page 3: ... RMS σ 7 7 nm Optical Rise Fall Time tr tf 2 ns 1 Output Eye Compliant with Bellcore TR NWT 000253 and ITU recommendation G 957 Receiver Sensitivity Avg PIN 31 dBm 2 Input Optical Wavelength λ 1310 nm LOS Deasserted Avg PA 31 dBm LOS Asserted Avg PD 48 dBm LOS Hysteresis PA PD 0 5 dB Overload PO 3 dBm Notes 1 These are unfiltered 10 90 values 2 The sensitivity is provided at a BER of 1 10 10 or be...

Page 4: ...l ID interface 6 MOD DEF0 Module Definition 0 3 Note 3 Grounded in Module 7 Rate Select Not Connect 3 Function not available 8 LOS Loss of Signal 3 Note 4 9 VeeR Receiver Ground 1 Note 5 10 VeeR Receiver Ground 1 Note 5 11 VeeR Receiver Ground 1 Note 5 12 RD Inv Received Data Out 3 Note 6 13 RD Received Data Out 3 Note 7 14 VeeR Receiver Ground 1 Note 5 15 VccR Receiver Power 2 3 3 5 Note 7 16 Vcc...

Page 5: ...n In the low state the output will be pulled to 0 8V 5 VeeR and VeeT may be internally connected within the SFP module 6 RD These are the differential receiver outputs They are AC coupled 100Ω differential lines which should be terminated with 100Ω differential at the user SERDES The AC coupling is done inside the module and is thus not required on the host board The voltage swing on these lines w...

Page 6: ... 01uF 0 01uF 0 1uF 10uF RES1 RES1 100 Ohms RES1 RES1 RES1 10k Ohms 100 Ohms VCC Protocol Vcc SerDes IC Protocol IC PLD PAL Mod_def 2 Mod_def 1 Mod_def 0 3 3V 3 3V DELTA SFP Module Preamp Tx_Disable Quantizer Tx_Fault TD TD VeeT RD RD Rx_LOS VeeR Tx_Disable Tx_Fault Rx_LOS RES1 4 7k to 10k Ohms VccT VccR Laser Driver Depands on SerDes IC used EEPROM ...

Page 7: ...DELTA ELECTRONICS INC 7 Jan 2008 Rev 0D www deltaww com Package Outline Drawing for Metal Housing with Bail de latch ...

Page 8: ...ABLE to when the modulated optical output rises above 90 of nominal Time to initialize including reset of TX_FAULT t_init 300 msec From power on or negation of TX_Fault using TX Disable TX Fault Assert Time t_fault 100 μsec Time from fault to TX fault on TX_DISABLE to reset t_rest 10 μsec Time TX Disable must be held high to reset TX_Fault LOS Assert Time t_loss_on 100 μsec Time from LOS state to ...

Page 9: ...SFP TX_DISABLE asserted Initialization during hot plugging of SFP TRANSCEIVER Example of initialization during hot plugging TX_DISABLE negated SFP TX_DISABLE timing during normal operation Detection of transmitter safety fault condition Successful recovery from transient safety fault condition Unsuccessful recovery from safety fault condition Timing of LOS detection ...

Page 10: ...108 00 09 00 34 20 59 20 84 DC Note 3 109 00 10 00 35 20 60 05 85 DC 110 00 11 03 36 00 61 1E 86 DC 111 00 12 01 37 00 62 00 87 DC 112 00 13 00 38 00 63 CS1 Note 1 88 DC 113 00 14 0F 39 00 64 00 89 DC 114 00 15 96 40 4C L 65 1A 90 DC 115 00 16 00 41 43 C 66 05 91 DC 116 00 17 00 42 50 P 67 05 92 00 117 00 18 00 43 2D 68 SN Note 2 93 00 118 00 19 00 44 31 1 69 SN 94 00 119 00 20 44 D 45 35 5 70 SN ...

Page 11: ...1000 4 2 IEC 801 2 Electrostatic Discharge to the Electrical Pins MIL STD 883E Method 3015 7 1 Satisfied with electrical characteristics of product spec 2 No physical damage Eye Safety US FDA CDRH AEL Class 1 EN 60950 2000 EN 60825 1 1994 A11 A2 EN 60825 2 2000 CDRH File 0321539 00 TUV Certificate No R50032471 Component Recognition Underwriters Laboratories and Canadian Standards Association Joint...

Page 12: ...re Blank 5 to 70 degree C H 10 to 85 degree C T 40 to 85 degree C Related Products z LCP 1250xxxx 1 25Gb s Multimode and single mode transceiver from 500m to 10km z LCP 2125xxxx 2 125Gb s Multimode and single mode transceiver from 300m to 10km z LCP 2488xxxx 2 5Gb s multimode and single mode transceiver from 300m to 15km ...

Reviews: