The Delphi Series Q48SR Quarter Brick, 48V input, adjustable single
output, isolated, open frame DC/DC converters are the latest offering
from a world leader in power systems technology and manufacturing  

Delta Electronics, Inc. This product family provides up to 165 watts of
power or up to 60A of output current in an industry standard footprint.
This product represents the next generation of design technology which
may be utilized to provide high levels of current at very low output
voltages required by today’s leading-edge circuitry. Utilizing an
advanced patented thermal and electrical design technology; the Delphi
Series Q48SR converters are capable of providing higher output current
capability with excellent transient response and lower common mode
noise. Featuring a wide operating output voltage range and high current
at low output voltages, these units offer more useable power over a
wide range of ambient operating conditions. The wide range trimmable
output feature allows the user to both reduce and standardize part
numbers across different and/or migrating voltage requirements. This
model covers the output range of 0.8V to 1.9V at 40A.  
 

Delphi Series Q48SR, 165W Quarter Brick Family
DC/DC Power Modules: 48V in, 1.8V/40A out

 

 
 

 

 

Datasheet 
DS_Q48SR1R840_12212004 

 

Delta Electronics, Inc.

APPLICATIONS 

 

Telecom/DataCom 

 

Wireless Networks 

 

Optical Network Equipment 

 

Server and Data Storage

 

 

Industrial/Test Equipment

 

 

OPTIONS 

 

 

Short lead lengths 

 

Non-latching over voltage protection

 

Negative trim 

 

Positive on/off logic

 

FEATURES  

 

High efficiency: 87% @ 1.8V/40A 

 

Standard footprint:  

57.9x36.8x10.2mm (2.28”x1.45”x0.40”) 

 

Industry standard pin out 

 

Fixed frequency operation 

 

Wide output trim range: 0.8V~1.9V 

 

Fully protected: OTP, OVP, OCP, UVLO 

 

No minimum load required 

 

Fast transient response 

 

Start up into pre-biased load 

 

Basic insulation 

 

ISO 9000, TL 9000, ISO 14001 certified 

manufacturing facility

 

 

UL/cUL 60950 (US & Canada) Recognized, 

and TUV (EN60950) Certified 

 

CE mark meets 73/23/EEC and 93/68/EEC 

directives 

Summary of Contents for Q48SR

Page 1: ... wide range of ambient operating conditions The wide range trimmable output feature allows the user to both reduce and standardize part numbers across different and or migrating voltage requirements This model covers the output range of 0 8V to 1 9V at 40A Delphi Series Q48SR 165W Quarter Brick Family DC DC Power Modules 48V in 1 8V 40A out Datasheet DS_Q48SR1R840_12212004 Delta Electronics Inc AP...

Page 2: ...ull Load 1µF ceramic 10µF tantalum 20 100 mV RMS Full Load 1µF ceramic 10µF tantalum 10 20 mV Operating Output Current Range 0 40 A Output DC Current Limit Inception Output Voltage 10 Low 105 130 DYNAMIC CHARACTERISTICS Output Voltage Current Transient 48V 10µF Tan 1µF Ceramic load cap 0 1A µs Positive Step Change in Output Current 50 Io max to 75 Io max 50 150 mV Negative Step Change in Output Cu...

Page 3: ...ltage at 25 C Vout 1 8V Figure 2 Power dissipation vs load current for minimum nominal and maximum input voltage at 25 C Vout 1 8V 60 65 70 75 80 85 10 20 30 40 OUTPUT CURRENT A EFFICIENCY 36Vin 48Vin 75Vin 0 0 2 0 4 0 6 0 8 0 10 0 12 0 14 0 10 20 30 40 OUTPUT CURRENT A POWER DISSIPATION W 36Vin 48Vin 75Vin Figure 3 Efficiency vs load current for minimum nominal and maximum input voltage at 25 C V...

Page 4: ...A Io 24A Io 4A Figure 5 Efficiency vs output voltage for minimum nominal and maximum input voltage at 25 C Iout 40A Figure 6 Power dissipation vs output voltage for minimum nominal and maximum input voltage at 25 C Iout 40A 75 77 79 81 83 85 87 89 91 93 95 0 8 1 0 1 2 1 4 1 6 1 8 OUTPUT VOLTAGE V EFFICIENCY 36Vin 48Vin 75Vin 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 0 8 1 0 1 2 1 4 1 6 1 8...

Page 5: ...rom the module Figure 11 Output voltage response to step change in load current 75 50 75 of Io max di dt 2 5A µs Load cap 470µF 35mΩ ESR solid electrolytic capacitor and 1µF ceramic capacitor Top Trace Vout 100mV div Bottom Trace Iout 20A div Scope measurement should be made using a BNC cable length shorter than 20 inches Position the load between 51 mm to 76 mm 2 inches to 3 inches from the modul...

Page 6: ... input voltage and rated load current 5 mA div Vo Vo 10u 1u Copper Strip SCOPE RESISTIVE LOAD Figure 15 Output voltage noise and ripple measurement test setup Figure 16 Output voltage ripple at nominal input voltage and rated load current 20 mV div Load capacitance 1µF ceramic capacitor and 10µF tantalum capacitor Bandwidth 20 MHz Scope measurement should be made using a BNC cable length shorter t...

Page 7: ...STICS CURVES 0 0 0 2 0 4 0 6 0 8 1 0 1 2 1 4 1 6 1 8 2 0 0 10 20 30 40 50 60 LOAD CURRENT A OUTPUT VOLTAGE V Vin 48V Figure 17 Output voltage vs load current showing typical current limit curves and converter shutdown points ...

Page 8: ...ding a 10 to 100 µF electrolytic capacitor ESR 0 7 Ω at 100 kHz mounted close to the input of the module to improve the stability Layout and EMC Considerations Delta s DC DC power modules are designed to operate in a wide variety of systems and applications For design assistance with EMC compliance and related PWB layout issues please contact Delta s technical support team An external input filter...

Page 9: ...ent exceeds the OCP set point the modules will automatically shut down hiccup mode The modules will try to restart after shutdown If the overload condition still exists the module will shut down again This restart trial will continue until the overload condition is corrected Over Voltage Protection The modules include an internal output over voltage protection circuit which monitors the voltage on...

Page 10: ...n i e 40 is written as 0 4 Ex When trim down to 0 8V from 1 8V Vonom 1 8V 1 8 0 8 1 8 0 5556 Ω Ω K K K down Rtrim 7 11 5556 0 10 Ω k The output voltage can be increased by both the remote sense and the trim however the maximum increase allowed is the larger of either the remote sense spec or the trim spec not the sum of both When using remote sense and trim the output voltage of the module is usua...

Page 11: ...uit cards in cabinet racks in which the power modules are mounted The following figure shows the wind tunnel characterization setup The power module is mounted on a test PWB and is vertically positioned within the wind tunnel The space between the neighboring PWB and the top of the power module is constantly kept at 6 35mm 0 25 Thermal Derating Heat can be removed by increasing airflow over the mo...

Page 12: ...FM Q48SR1R840 Standard Output Current vs Ambient Temperature and Air Velocity Vin 48V Vo 1 5V Tranverse Orientation 0 5 10 15 20 25 30 35 40 45 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature Output Current A Natural Convection 100LFM 200LFM 300LFM 400LFM 500LFM 600LFM Figure 25 Output current vs ambient temperature and air velocity Vin 48V Vout 1 8V transverse orientation Q48SR1R840...

Page 13: ...t Negative input voltage Remote ON OFF Positive input voltage Positive output voltage Positive remote sense Output voltage trim Negative remote sense Negative output voltage Notes 1 2 3 Pins 1 3 5 7 are 1 00mm 0 040 diameter Pins 4 and 8 are 1 50mm 0 060 diameter All pins are copper with tin plating ...

Page 14: ...t fixed output voltages CONTACT www delta com tw dcdc USA Telephone East Coast 888 335 8201 West Coast 888 335 8208 Fax 978 656 3964 Email DCDC delta corp com Europe Telephone 41 31 998 53 11 Fax 41 31 998 53 53 Email DCDC delta es tw Asia the rest of world Telephone 886 3 4526107 x6220 Fax 886 3 4513485 Email DCDC delta com tw WARRANTY Delta offers a two 2 year limited warranty Complete warranty ...